Raman and IR Spectroscopy Studies on Propane at Pressures of Up to 40 GPa

Daniil Kudryavtsev1, Alexander Serovaiskii1, Elena Mukhina1

  • 1Department of Energy Technology Royal Institute of Technology , 100 44 Stockholm, Sweden.

Related Concept Videos

Conformations of Ethane and Propane02:18

Conformations of Ethane and Propane

In an organic molecule, free rotation about the carbon-carbon single bond results in energetically different conformers of the molecule. Due to this rotation, called the internal rotation, ethane has two major conformations — staggered and eclipsed.
Staggered conformation is a low energy and more stable conformation with the C-H bonds on the front carbon placed at 60°dihedral angles relative to the C-H bonds on the back carbon, leading to a reduced torsional strain. In staggered...
18.2K
Raman Spectroscopy: Overview01:20

Raman Spectroscopy: Overview

The underlying principle of Raman spectroscopy is based on the interaction between light and matter, specifically molecules' inelastic scattering of photons. When a monochromatic beam of light, typically from a laser source, interacts with a sample, most scattered light has the same frequency as the incident light. This is known as Rayleigh scattering.
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
2.0K
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution00:52

¹H NMR of Conformationally Flexible Molecules: Temporal Resolution

At room temperature, the chair conformer of cyclohexane undergoes rapid ring flipping between two equivalent chair conformers at a rate of approximately 105 times per second. These two chair conformers are in equilibrium. The rapid ring flipping results in the interconversion of the axial proton to an equatorial proton and an equatorial to the axial proton. Such interconversions are too rapid and cannot be detected on the NMR timescale. Hence, the NMR spectrometer cannot distinguish between the...
1.3K
Conformations of Cycloalkanes02:29

Conformations of Cycloalkanes

Adolf von Baeyer attempted to explain the instabilities of small and large cycloalkane rings using the concept of angle strain — the strain caused by the deviation of bond angles from the ideal 109.5° tetrahedral value for sp3  hybridized carbons. However, while cyclopropane and cyclobutane are strained, as expected from their highly compressed bond angles, cyclopentane is more strained than predicted, and cyclohexane is virtually strain-free. Hence, Baeyer’s theory that...
15.6K
Raman Spectroscopy Instrumentation: Overview01:26

Raman Spectroscopy Instrumentation: Overview

A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
1.4K
¹H NMR: Complex Splitting01:13

¹H NMR: Complex Splitting

A proton M that is coupled to a proton X results in doublet signals for M. However, NMR-active nuclei can be simultaneously coupled to more than one nonequivalent nucleus. When M is coupled to a second proton A, such as in styrene oxide, each peak in the doublet is split into another doublet.
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...
2.0K