Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

1.3K
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
1.3K
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

1.7K
There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
1.7K
Gas Chromatography: Overview of Detectors01:13

Gas Chromatography: Overview of Detectors

2.1K
Detectors in gas chromatography (GC) help identify and quantify the components of a mixture by translating chemical properties into measurable signals, which are displayed on a chromatogram. Detectors can be categorized into two main types: destructive and non-destructive.
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
2.1K
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

1.9K
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
1.9K
Gas Chromatography: Introduction01:13

Gas Chromatography: Introduction

4.2K
Gas chromatography (GC) is a technique for separating and analyzing volatile compounds in a sample. Its primary purpose is to identify and quantify components in complex mixtures, making it essential in fields such as environmental analysis, pharmaceuticals, and petrochemicals. GC is also called vapor-phase chromatography (VPC) or gas-liquid partition chromatography (GLPC).
In GC,  a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
4.2K
Amperometry: Overview01:10

Amperometry: Overview

1.9K
Amperometry is a technique commonly used to measure the concentration of specific analytes in a solution by monitoring the electric current generated during an electrochemical reaction. It involves applying a constant potential between a working electrode and a reference electrode to measure the resulting current, which is proportional to the concentration of the analyte. The Clark oxygen electrode operates based on this principle of amperometry. It consists of a cathode and an anode enclosed...
1.9K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The Military Health System Data Repository: Leveraging Closed, Familial-Linked Electronic Health Record Data for a Large Generalizable US Population.

Pharmacoepidemiology and drug safety·2026
Same author

Vacancy-driven twinning in metal nanoparticles: from bulk morphology transformation to optical and electrochemical effects.

Nanoscale·2026
Same author

Electrochemical determination of ammonia at low concentrations: detection of N<sub>2</sub>-electroreduction product in alkaline medium.

Talanta·2025
Same author

Protective Properties of Silane Composite Coatings Modified with Poly(3,4-ethylenedioxythiophene) with Heteropolyacid on X20Cr13 and 41Cr4 Steel.

Materials (Basel, Switzerland)·2025
Same author

Enhanced Visible Light Controlled Glucose Photo-Reforming Using a Composite WO<sub>3</sub>/Ag/TiO<sub>2</sub> Photoanode: Effect of Incorporated Plasmonic Ag Nanoparticles.

Nanomaterials (Basel, Switzerland)·2024
Same author

Inorganic-organic modular silicon and dye-sensitized solar cells and predicted role of artificial intelligence towards efficient and stable solar chargers based on supercapacitors.

Scientific reports·2024

Related Experiment Video

Updated: Feb 26, 2026

Encapsulating Cytochrome c in Silica Aerogel Nanoarchitectures without Metal Nanoparticles while Retaining Gas-phase Bioactivity
11:06

Encapsulating Cytochrome c in Silica Aerogel Nanoarchitectures without Metal Nanoparticles while Retaining Gas-phase Bioactivity

Published on: March 1, 2016

10.8K

Amperometric detector for gas chromatography based on a silica sol-gel solid electrolyte.

William H Steinecker1, Krzysztof Miecznikowski2, Pawel J Kulesza2

  • 1VGC Chromatography, Dayton, OH, USA.

Talanta
|July 26, 2017
PubMed
Summary

This study introduces a novel amperometric detector for gas chromatography using a silica sol-gel solid electrolyte. This electrochemical cell enables sensitive detection of various analytes in the gas phase.

Keywords:
Amperometric detectorConstant applied potentialGas phaseSilica sol-gel electrolyte

More Related Videos

Author Spotlight: Standardizing the Development of Amine-Based Silica Composites as CO2 Adsorbents for Direct Air Capture
08:00

Author Spotlight: Standardizing the Development of Amine-Based Silica Composites as CO2 Adsorbents for Direct Air Capture

Published on: September 29, 2023

3.3K
Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
07:57

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector

Published on: July 25, 2014

20.5K

Related Experiment Videos

Last Updated: Feb 26, 2026

Encapsulating Cytochrome c in Silica Aerogel Nanoarchitectures without Metal Nanoparticles while Retaining Gas-phase Bioactivity
11:06

Encapsulating Cytochrome c in Silica Aerogel Nanoarchitectures without Metal Nanoparticles while Retaining Gas-phase Bioactivity

Published on: March 1, 2016

10.8K
Author Spotlight: Standardizing the Development of Amine-Based Silica Composites as CO2 Adsorbents for Direct Air Capture
08:00

Author Spotlight: Standardizing the Development of Amine-Based Silica Composites as CO2 Adsorbents for Direct Air Capture

Published on: September 29, 2023

3.3K
Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
07:57

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector

Published on: July 25, 2014

20.5K

Area of Science:

  • Electrochemistry
  • Analytical Chemistry
  • Materials Science

Background:

  • Gas chromatography (GC) requires sensitive detectors for analyzing volatile compounds.
  • Solid electrolytes offer advantages in electrochemical devices, including stability and ease of handling.
  • Maintaining stable operating conditions, such as humidity, is crucial for reproducible electrochemical measurements.

Purpose of the Study:

  • To develop and evaluate a novel amperometric detector for gas chromatography (GC) utilizing a silica sol-gel solid electrolyte.
  • To investigate the detector's response to various gaseous analytes.
  • To assess the performance of the detector in terms of response time and detection limits.

Main Methods:

  • Fabrication of an electrochemical cell with a silica sol-gel solid electrolyte, a working electrode in the gas phase, and reference/counter electrodes.
  • Operation of the cell under potentiostatic conditions for amperometric detection.
  • Testing the detector with various analytes including hydrogen, thiols, phenols, and thioanisole.
  • Utilizing flow injection analysis and GC separation with helium and other carrier gases.

Main Results:

  • The electrochemical cell demonstrated response to hydrogen, 1,2-ethandithiol, phenol, p-cresol, and thioanisole.
  • Rapid response time for hydrogen detection (<1s for 90% steady-state current at 20 mL/min).
  • Achieved separation and detection limits (k=3) for 1,2-ethandithiol (4 ppmv), phenol (1 ppmv), p-cresol (3 ppmv), and thioanisole (70 ppmv) at 800mV and 2.2 mL/min flow rate.

Conclusions:

  • The developed silica sol-gel based amperometric detector is effective for gas chromatography.
  • The detector exhibits fast response and sensitive detection capabilities for a range of analytes.
  • The integrated humidistat function of the sol-gel electrolyte ensures stable performance.