Iliac Stent Migration during Thoracic Endovascular Aortic Aneurysm Repair Resulting in Functional Coarctation
Jamie Clementi1, Sungho Lim1, Pegge Halandras1
1Department of Surgery, Division of Vascular Surgery and Endovascular Therapy, Loyola University Chicago, Stritch School of Medicine, Maywood, IL.
Abstract:
Iliac arterial disease, unfavorable anatomy, and prior stenting all pose challenges to access in endovascular abdominal aortic repair (EVAR) and thoracic aortic repair (TEVAR). Iliac access injury during T/EVAR may lead to rupture, dissection, thrombosis, or distal ischemia. Some have advocated iliac stent prior to T/EVAR in patients with suboptimal iliac access. The rate of complication and iliac stent migration during subsequent T/EVAR is undocumented. This case report describes a unique instance of self-expanding iliac stent migration during TEVAR which pinched the thoracic aortic endograft causing functional aortic coarctation.