Related Experiment Video
Updated: Feb 25, 2026

Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
End-Expiratory Occlusion Test Predicts Fluid Responsiveness in Patients With Protective Ventilation in the Operating
Matthieu Biais1,2, Mathilde Larghi1, Jeremy Henriot1
1From the Department of Anesthesiology and Critical Care III, Bordeaux University Hospital, Bordeaux, France.
Background:
End-expiratory occlusion test (EEOT) has been proposed to predict fluid responsiveness in mechanically ventilated intensive care unit patients. The utility of this test during low-tidal-volume ventilation remains uncertain. This study aimed to determine whether hemodynamic variations induced by EEOT could predict the effect of volume expansion in patients with protective ventilation in the operating room.
Methods:
Forty-one patients undergoing neurosurgery were included. Stroke volume and pulse pressure variations were continuously recorded using pulse contour analysis before and immediately after a 30-second EEOT and after volume expansion (250 mL saline 0.9% given over 10 minutes). Patients with an increase in stroke volume ≥ 10% after volume expansion were defined as responders.
Results:
Twenty patients were responders to fluid administration. EEOT induced a significant increase in stroke volume, which was correlated with the stroke volume changes induced by volume expansion (r = 0.55, P < .0001). A 5% increase in stroke volume during EEOT discriminated responders to volume expansion with a sensitivity of 100% (95% confidence interval [CI], 83%-100%), a specificity of 81% (95% CI, 58%-95%), a positive predictive value of 84% (95% CI, 64%-96%), and a negative predictive value of 100% (95% CI, 80%-100%). The gray zone ranged from 4% to 8%, including 17% of patients. The best pulse pressure variation threshold was 9%, with a sensitivity of 60% (95% CI, 36%-81%) and specificity of 86% (95% CI, 64%-97%). The area under the receiver operating characteristics curve generated for changes in stroke volume induced by EEOT (0.91, 95% CI, 0.81-1.00) was significantly higher than the one obtained for pulse pressure variations (0.75, 95% CI, 0.60-0.90); P < .05.
Conclusions:
Changes in stroke volume index induced by EEOT can predict fluid responsiveness in patients with protective ventilation in the operating room. This test may have potential applications.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...

