Related Experiment Video
Updated: Feb 25, 2026

Use of the Scissor-Type Knife During the Peroral Endoscopy Myotomy Procedure for the Treatment of Achalasia
Published on: March 3, 2023
Endoscopic submucosal dissection of gastric adenomas using the clutch cutter
Kazuya Akahoshi1, Masaru Kubokawa1, Junya Gibo1
1Kazuya Akahoshi, Masaru Kubokawa, Junya Gibo, Shigeki Osada, Kayo Tokumaru, Eriko Yamaguchi, Hiroko Ikeda, Takao Sato, Kazuaki Miyamoto, Yusuke Kimura, Yuki Shiratsuchi, Kazuaki Akahoshi, Department of Gastroenterology, Aso Iizuka Hospital, Iizuka 820-8505, Japan.
Aim:
To evaluate the efficacy and safety of endoscopic submucosal dissection (ESD) using the clutch cutter (CC) (ESD-CC) for gastric adenoma (GA).
Methods:
From June 2007 to August 2015, 122 consecutive patients with histological diagnoses of GA from specimens resected by ESD-CC were enrolled in this prospective study. The CC was used for all ESD steps (marking, mucosal incision, submucosal dissection, and hemostatic treatment), and its therapeutic efficacy and safety were assessed.
Results:
Both the en-bloc resection rate and the R0 resection rate were 100% (122/122). The mean surgical time was 77.4 min, but the time varied significantly according to tumor size and location. No patients suffered perforation. Post-ESD-CC bleeding occurred in six cases (4.9%) that were successfully resolved by endoscopic hemostatic treatment.
Conclusion:
ESD-CC is a technically efficient, safe, and easy method for resecting GA.