Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Radiation reduction during percutaneous coronary intervention: A new protocol with a low frame rate and selective
Min Ku Chon1, Kook Jin Chun, Dae Sung Lee
1Division of Cardiology, Department of Internal Medicine, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea.
Abstract:
The percutaneous coronary intervention (PCI) procedure is associated with potentially high levels of radiation exposure and therefore increased risk of adverse radiation-induced outcomes, ranging from cataract to malignancy. Frame rate reduction and selective fluoroscopy storage may help reduce radiation exposure. In this study, we evaluated the efficacy of a radiation reduction protocol that uses a lower frame rate and selective storage of fluoroscopic images in terms of its effect on reducing the radiation dose during PCI.The new protocol incorporated a lower frame rate as compared with the conventional protocol, and used selective storage of fluoroscopic images. We reviewed the medical records of patients who underwent PCI under the conventional protocol from January 2013 to December 2013, and compared them with those who underwent PCI with the new protocol from January 2015 to December 2015. The primary endpoint was radiation dose reduction expressed as cumulative air kerma and dose-area product (DAP). The image quality was assessed by 3 independent well-trained cardiologists.One hundred fifty-five patients were enrolled in the conventional protocol group, and 152 were enrolled in the radiation reduction protocol group (total, n = 307). There was no statistical significance in terms of the baseline characteristics, including body mass index. Overall, the radiation reduction protocol group showed a significant reduction in both cumulative air kerma (1634.39 ± 717.95 vs 2074.75 ± 1003.72 mGy, P < .001) and DAP (12344.86 ± 5371.75 vs 15312.19 ± 7136.58 μGy m, P < .001). Image quality was acceptable in both groups.The radiation reduction protocol, which uses a lower frame rate and selective storage of fluoroscopic images, may be an alternative approach to reducing PCI radiation dose.
More Related Videos
08:30X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...