Integrated Compensatory Responses in a Human Model of Hemorrhage
Published on: November 20, 2016
Wearable technology for compensatory reserve to sense hypovolemia
Victor A Convertino1, Michael N Sawka2
1Battlefield Health & Trauma Center for Human Integrative Physiology, U. S. Army Institute of Surgical Research, Joint Base San Antonio-Fort Sam Houston, San Antonio, Texas.
Abstract:
Traditional monitoring technologies fail to provide accurate or early indications of hypovolemia-mediated extremis because physiological systems (as measured by vital signs) effectively compensate until circulatory failure occurs. Hypovolemia is the most life-threatening physiological condition associated with circulatory shock in hemorrhage or sepsis, and it impairs one's ability to sustain physical exertion during heat stress. This review focuses on the physiology underlying the development of a novel noninvasive wearable technology that allows for real-time evaluation of the cardiovascular system's ability to compensate to hypovolemia, or its compensatory reserve, which provides an individualized estimate of impending circulatory collapse. Compensatory reserve is assessed by real-time changes (sampled millions of times per second) in specific features (hundreds of features) of arterial waveform analog signals that can be obtained from photoplethysmography using machine learning and feature extraction techniques. Extensive experimental evidence employing acute reductions in central blood volume (using lower-body negative pressure, blood withdrawal, heat stress, dehydration) demonstrate that compensatory reserve provides the best indicator for early and accurate assessment for compromises in blood pressure, tissue perfusion, and oxygenation in resting human subjects. Engineering challenges exist for the development of a ruggedized wearable system that can measure signals from multiple sites, improve signal-to-noise ratios, be customized for use in austere conditions (e.g., battlefield, patient transport), and be worn during strenuous physical activity.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Heart Failure VI: Adjunct Therapies
Body Water Content and Fluid Compartments
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement