A Probing Device for Quantitatively Measuring the Mechanical Properties of Soft Tissues during Arthroscopy
Published on: May 1, 2020
Optimal Regression Method for Near-Infrared Spectroscopic Evaluation of Articular Cartilage
Mithilesh Prakash1, Jaakko K Sarin1,2, Lassi Rieppo1,3
11 Department of Applied Physics, University of Eastern Finland, Kuopio, Finland.
Abstract:
Near-infrared (NIR) spectroscopy has been successful in nondestructive assessment of biological tissue properties, such as stiffness of articular cartilage, and is proposed to be used in clinical arthroscopies. Near-infrared spectroscopic data include absorbance values from a broad wavelength region resulting in a large number of contributing factors. This broad spectrum includes information from potentially noisy variables, which may contribute to errors during regression analysis. We hypothesized that partial least squares regression (PLSR) is an optimal multivariate regression technique and requires application of variable selection methods to further improve the performance of NIR spectroscopy-based prediction of cartilage tissue properties, including instantaneous, equilibrium, and dynamic moduli and cartilage thickness. To test this hypothesis, we conducted for the first time a comparative analysis of multivariate regression techniques, which included principal component regression (PCR), PLSR, ridge regression, least absolute shrinkage and selection operator (Lasso), and least squares version of support vector machines (LS-SVM) on NIR spectral data of equine articular cartilage. Additionally, we evaluated the effect of variable selection methods, including Monte Carlo uninformative variable elimination (MC-UVE), competitive adaptive reweighted sampling (CARS), variable combination population analysis (VCPA), backward interval PLS (BiPLS), genetic algorithm (GA), and jackknife, on the performance of the optimal regression technique. The PLSR technique was found as an optimal regression tool (R2Tissue thickness = 75.6%, R2Dynamic modulus = 64.9%) for cartilage NIR data; variable selection methods simplified the prediction models enabling the use of lesser number of regression components. However, the improvements in model performance with variable selection methods were found to be statistically insignificant. Thus, the PLSR technique is recommended as the regression tool for multivariate analysis for prediction of articular cartilage properties from its NIR spectra.
More Related Videos
06:50O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
08:06Addressing Practical Issues in Atomic Force Microscopy-Based Micro-Indentation on Human Articular Cartilage Explants
Published on: October 28, 2022
Related Concept Videos
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to...
UV–Vis Spectroscopy: Woodward–Fieser Rules
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...