Related Experiment Video
Updated: Feb 25, 2026

Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
A new composite measure of colonoscopy: the Performance Indicator of Colonic Intubation (PICI)
Roland M Valori1, Sarah Damery2, Daniel R Gavin3
1Department of Gastroenterology, Gloucestershire Hospitals NHS Foundation Trust, Gloucester, United Kingdom.
Background And Study Aim:
Cecal intubation rate (CIR) is an established performance indicator of colonoscopy. In some patients, cecal intubation with acceptable tolerance is only achieved with additional sedation. This study proposes a composite Performance Indicator of Colonic Intubation (PICI), which combines CIR, comfort, and sedation. METHODS : Data from 20 085 colonoscopies reported in the 2011 UK national audit were analyzed. PICI was defined as the percentage of procedures achieving cecal intubation with median dose (2 mg) of midazolam or less, and nurse-assessed comfort score of 1 - 3/5. Multivariate logistic regression analysis evaluated possible associations between PICI and patient, unit, colonoscopist, and diagnostic factors. RESULTS : PICI was achieved in 54.1 % of procedures. PICI identified factors affecting performance more frequently than single measures such as CIR and polyp detection, or CIR + comfort alone. Older age, male sex, adequate bowel preparation, and a positive fecal occult blood test as indication were associated with a higher PICI. Unit accreditation, the presence of magnetic imagers in the unit, greater annual volume, fewer years' experience, and higher training/trainer status were associated with higher PICI rates. Procedures in which PICI was achieved were associated with significantly higher polyp detection rates than when PICI was not achieved. CONCLUSIONS : PICI provides a simpler picture of performance of colonoscopic intubation than separate measures of CIR, comfort, and sedation. It is associated with more factors that are amenable to change that might improve performance and with higher likelihood of polyp detection. It is proposed that PICI becomes the key performance indicator for intubation of the colon in colonoscopy quality improvement initiatives.
More Related Videos
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
03:43Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Methods of Documentation III: PIE
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...