Oval housing for the St. Jude Medical bileaflet mechanical heart valve
Hadi Mohammadi1,2,3, Guy Fradet1,3
11 The Heart Valve Performance Laboratory, School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, Canada.
Abstract:
The St. Jude Medical bileaflet mechanical heart valve was approved by the Food and Drug Administration in late 1970s. The basic idea for the design of the valve is simply two semicircular flat plates pivoting on hinges. The overall performance of St. Jude Medical valves such as blood flow being central, the leaflets opening completely, and the pressure drop across the valve being trivial is satisfactory. St. Jude Medical valves provide an improved hemodynamics compared to the other mechanical heart valve models; however, their non-physiological hemodynamics which may lead to red blood cells lysis and thrombogenicity still remains a major issue. In this study, we hypothesize that applying ovality to the housing might improve their hemodynamics significantly which is based on the fact that the native annulus is oval by nature. A quick but precise numerical model based on the finite strip method was developed by which the regurgitation flow volume and velocity of the proposed design were assessed in the closing phase. The results are satisfactory and an improved hemodynamics is observed. The proposed design can be considered for further numerical and experimental studies and shows promise and merits further development.
More Related Videos
12:17Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Mitral Stenosis III: Medical Management
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Stenosis I: Introduction
Mitral Regurgitation III: Medical Management
Mitral Valve Prolapse III: Nursing Management
Mitral Stenosis IV: Nursing Management