Related Experiment Video
Updated: Feb 25, 2026

Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
Assessment of left ventricular function in healthy Great Danes and in Great Danes with dilated cardiomyopathy using
B Pedro1, H Stephenson2, C Linney2
1University of Liverpool School of Veterinary Science, Neston, UK; Willows Veterinary Centre and Referral Service, West Midlands, UK.
Objectives:
Assess global circumferential and radial systolic and diastolic myocardial function with speckle tracking echocardiography (STE) in healthy Great Danes (GD) and in GD diagnosed with dilated cardiomyopathy (DCM).
Animals:
Eighty-nine GD were included in the study: 39 healthy (normal group [NORMg]) and 50 diagnosed with DCM (DCMg).
Methods:
This was a retrospective study. Signalment and echocardiographic diagnosis were obtained from the medical records of GD assessed between 2008 and 2012. Speckle tracking echocardiography analysis of circumferential (C) and radial (R) strain (St) and strain rate (SR) in systole (S), early (E) and late (A) diastole was performed at the levels of the mitral valve (MV), papillary muscles (PM) and apex (Ap) of the left ventricle. Univariable and multivariable analysis was performed to identify differences between groups.
Results:
Speckle tracking echocardiography variables increase from the MV towards the Ap of the left ventricle in both NORMg and DCMg dogs, some reaching statistical significance. Most of the variables (28/31) were lower in DCMg than in NORMg dogs: statistically significant variables included radial SR at the Ap in systole (p=0.029), radial strain at the PM (p=0.012), circumferential SR at the PM in systole (p=0.031), circumferential and radial SR at the MV in early diastole (p=0.019 and p=0.049, respectively).
Conclusions:
There are significant differences in STE variables between NORMg and DCMg Great Danes, although the overlap between the two groups may indicate that these variables are not sufficiently discriminatory. STE variables are not sufficiently sensitive to use in isolation as a screening method.