Related Experiment Video
Updated: Feb 25, 2026

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
CT- versus MRI-based patient-specific instrumentation for total knee arthroplasty: A systematic review and
Xiang-Dong Wu1, Bing-Yan Xiang2, Martijn G M Schotanus3
1Department of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China; Evidence-Based Perioperative Medicine 07 Collaboration Group, China.
Background:
To determine whether computed tomography (CT) or magnetic resonance imaging (MRI) is more suitable for the patient-specific instrumentation (PSI) systems for total knee arthroplasty (TKA).
Methods:
PubMed, Embase, and the Cochrane Library were searched from inception to June 2016 for prospective comparative trials that compared CT- versus MRI-based PSI systems for TKA. Our predefined primary outcome was the outliers incidence of coronal overall limb alignment.
Results:
Six studies with a total of 336 knees meeting the eligibility criteria, and four trials were included in the meta-analysis. Compared with MRI-based PSI systems, CT-based PSI systems were associated with a higher outliers incidence of coronal overall limb alignment (risk ratio: 1.67; 95% confidence interval (CI): 1.03-2.72; P = 0.04), more angular errors of coronal overall limb alignment (mean difference (MD): 1.01°; 95% CI: 0.47-1.56; P = 0.0003), and longer operation time (MD: 5.02 min; 95% CI: 1.26-8.79; P = 0.009). While no significant differences in the coronal/sagittal alignment of the femoral/tibial component outliers, the angular errors of coronal overall limb alignment, the angular errors of the femoral/tibial component in coronal plane, or incidence of change of implant size of the femoral/tibial component were observed.
Conclusions:
The current limited evidence suggests that MRI-based PSI systems exhibit higher accuracy for TKA regarding the coronal limb axis than CT-based PSI systems. However, well-designed studies comparing CT-versus MRI-based PSI systems for TKA are warrant to confirm these results before widespread use of this technique can be recommended.