Related Experiment Video
Updated: Feb 25, 2026

Measurement of Heart Contractility in Isolated Adult Human Primary Cardiomyocytes
Published on: August 9, 2022
Non-contact measurement of heart response reflected in human eye
Sangin Park1, Myoung Ju Won1, Dong Won Lee2
1Seoul Industry-Academy Cooperation Team, Sangmyung University, 7 Hongji-dong, Jongro-Ku, Seoul 110-743, Republic of Korea.
Abstract:
This study aims to develop a non-contact measurement technique for cardiac response that uses an infrared image of the patient's pupil. The pupil contraction rhythm is related to the autonomic balance and major organs (such as the heart) via a neural pathway. In this study, the response of the heart was determined by analyzing the pupillary rhythm based on the harmonic frequencies between them. Seventy undergraduate volunteers of both genders, (35 females and 35 males), with ages ranging between 20 and 30years (mean: 24.52±0.64years) were asked to conduct a simple conversation, perform slight movements, and experience sound stimuli to evoke arousal, relaxation, happiness, sadness, or a neutral mood in this experiment. Electrocardiograms and pupil images were measured and analyzed, and the harmonic frequencies were identified to determine the relational response. The cardiac time (heart rate (HR), beats per minute (BPM), the standard deviation of the normal-to-normal (NN) intervals (SDNN), the mean squared differences in the successive N-N intervals (rMSSD), and the percentage difference between adjacent normal interbeat (R-R) intervals>50 (pNN50)) and frequency (very low frequency (VLF), low frequency (LF), high frequency (HF), VLF/HF, and LF/HF) parameters were also observed with regard to the effects of the movement, conversation, and physiological state. The cardiac response was stable, showing less significance than the effects of the three conditions. Therefore, multi-cardiac measurements were successfully obtained from a simple, low-cost, non-invasive, and non-contact data acquisition method in this study.
More Related Videos
10:41Using Electroencephalography Measurements and High-quality Video Recording for Analyzing Visual Perception of Media Content
Published on: May 26, 2018
08:22Author Spotlight: Advancing the Study of Brain-Heart Interplay with a Comprehensive EEGLAB Plugin for Multimodal Signal Analysis
Published on: April 26, 2024
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...