Comparison of air samplers for determination of isocyanic acid and applicability for work environment exposure
Mikolaj Jan Jankowski1, Raymond Olsen, Yngvar Thomassen
1National Institute of Occupational Health, P.O. Box 8149, N-0033, Oslo, Norway. mikolaj.jankowski@stami.no.
Abstract:
Isocyanic acid (ICA) is one of the most abundant isocyanates formed during thermal decomposition of polyurethane (PUR), and other nitrogen containing polymers. Hot-work, such as flame cutting, forging, grinding, turning and welding may give rise to thermal decomposition of said polymers potentially forming significant amounts of ICA. A newly launched dry denuder sampler for airborne isocyanates using di-n-butylamine (DBA) demonstrated build-up of background ICA-DBA over time. Build-up of background ICA-DBA was not observed when stored at inert conditions (Ar atmosphere) for 84 days. Thus, freshly prepared denuders were used. The sampling efficiency of ICA using freshly prepared denuder samplers (0.2 L min-1), impinger + filter samplers (0.5 L min-1) using DBA and 1-(2-methoxyphenyl) piperazine (2MP)-impregnated filter cassette samplers (1 L min-1) was investigated. PTR-MS measurements of ICA were used as a quantitative reference. Dynamically generated standard ICA atmospheres covered the range 5.6 to 640 ppb at absolute humidities (AH) 4.0 and 16 g m-3. Recovered ICA was found to be 73-115% (denuder), 89-115% (impinger + filter) and 62-100% (2MP filter cassette). The method limit of detection (LOD) was equal to an amount of ICA of 24 ng (denuder), 8.9 ng (impinger + filter) and 9.4 ng (2MP filter cassette). The PTR-MS LOD for ICA was 1.8 and 2.8 ppb in atmospheres with an AH of 4 and 16 g m-3. Denuder samplers were used for personal (n = 176) and stationary (n = 31) air sampling during hot-work at six industrial sites (n = 23 workers). ICA was detected above method LOD in 66% and 58% of the personal and stationary samples, respectively. ICA workroom air concentrations were determined to be 1.8-320 ppb (median 12 ppb) (personal samples), and 1.5-44 ppb (median 6.6 ppb) (stationary samples).
More Related Videos
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
10:34Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...