Related Experiment Video
Updated: Feb 25, 2026

Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Endocuff-assisted colonoscopy is associated with a lower adenoma miss rate: a multicenter randomized tandem study
Konstantinos Triantafyllou1, Dimitrios Polymeros1, Periklis Apostolopoulos2
1Hepatogastroenterology Unit, 2nd Department of Internal Medicine-Propaedeutic, Research Institute and Diabetes Center, Medical School, National and Kapodistrian University, Attikon University General Hospital, Athens, Greece.
Abstract:
Background and study aims The Endocuff (ARC Medical Design, Leeds, UK) is a device that, when mounted on the tip of an endoscope, may assist with inspection of a greater surface of the colonic mucosa by pulling backwards, flattening, and stretching the colonic folds as the endoscope is gradually withdrawn. We aimed to compare the adenoma miss rates of Endocuff-assisted colonoscopy with those of conventional colonoscopy. Patients and methods The included patients underwent same-day, back-to-back, (Endocuff-assisted colonoscopy as the index procedure followed by conventional colonoscopy or vice versa, randomly assigned 1:1) colonoscopies, performed by six endoscopists with documented adenoma detection rates > 35 %, in four tertiary endoscopy facilities. Results We randomized 200 patients (mean age 61.2 years [standard deviation 9.8]; 86.5 % colorectal cancer screening surveillance cases). Overall, there were seven incomplete examinations using Endocuff and one with conventional colonoscopy (P = 0.03). Times for endoscope insertion (5.0 minutes [0.8 - 21.0] vs. 5.0 minutes [1.0 - 16.0]; P = 0.49) and withdrawal (6.0 minutes [3.2 - 29.0] vs. 6.0 minutes [3.1 - 17.0]; P = 0.06) were similar for Endocuff-assisted and conventional colonoscopy. We detected one cancer and 195 adenomas; 84 in the proximal colon. Endocuff-assisted colonoscopy showed significantly lower overall and proximal colon adenoma miss rates compared with conventional colonoscopy (14.7 % [8.0 % - 21.0 %] vs. 38.4 % [28.1 % - 48.6 %] and 10.4 % [1.8 % - 19.1 %] vs. 38.9 % [23.0 % - 54.8 %], respectively). No difference between the two arms was shown regarding advanced adenoma miss rates, either overall or in the proximal colon. There were no serious adverse events related to the procedures. Conclusions In comparison with conventional colonoscopy, Endocuff-assisted colonoscopy has a significantly lower adenoma miss rate when performed by high-detector endoscopists. However, the incomplete colonoscopy rate with Endocuff is higher.ClinicalTrials.gov Identifier: NCT02340065.
More Related Videos
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
08:26Clinical Application of Single-Surgeon, Three-Port, Laparoscopic Resection for Colorectal Cancer with Natural Orifice Specimen Extraction
Published on: March 24, 2023
Related Concept Videos
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures III: Video Capsule Endoscopy
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...
Urologic Endoscopic Procedure: Cystoscopic Examination