Related Experiment Video
Updated: Feb 25, 2026

A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique
Published on: January 6, 2023
Can the possibility of transverse iliosacral screw fixation for first sacral segment be predicted preoperatively?
Jin-Hoon Jeong1, Jin Woo Jin2, Byoung Youl Kang2
1Department of Orthopaedic Surgery, Gyeongsang National University, College of Medicine, Gyeongsang National University Changwon Hospital, 11, Samjeongja-ro, Seongsan-gu, Changwon-si, Gyeongsangnam-do, 51472, Republic of Korea.
Objectives:
The purpose of this study was to predict the possibility of transverse iliosacral (TIS) screw fixation into the first sacral segment (S1) and introduce practical anatomical variables using conventional computed tomography (CT) scans.
Materials And Methods:
A total of 82 cadaveric sacra (42 males and 40 females) were used for continuous 1.0-mm slice CT scans, which were imported into Mimics® software to produce a three-dimensional pelvis model. The anterior height (BH) and superior width (BW) of the elevated sacral segment was measured, followed by verification of the safe zone (SZS1 and SZS2) in a true lateral view. Their vertical (VDS1 and VDS2) and horizontal (HDS1 and HDS2) distances were measured. VDS1 less than 7mm was classified as impossible sacrum, since the transverse fixation of 7.0 mm-sized IS screw could not be done safely.
Results:
Fourteen models (16.7%; six females, eight males) were assigned as the impossible sacrum. There was no statistical significance regarding gender (p=0.626) and height (p=0.419). The average values were as follows: BW, 31.4mm (SD 2.9); BH, 16.7mm (SD 6.8); VDS1, 13.4mm (SD 6.1); HDS1, 22.5mm (SD 4.5); SZS1, 239.5mm2 (SD 137.1); VDS2, 15.5mm (SD 3.0); HDS2, 18.3mm (SD 2.9); and SZS2, 221.1mm2 (SD 68.5). Logistic regression analysis identified BH (p=0.001) and HDS1 (p=0.02) as the only statistically significant variables to predict the possibility. Receiver operating characteristic curve analysis established a cut-off value for BH and HDS1 of impossible sacrum of 20.6mm and 18.6mm, respectively.
Conclusion:
BH and HDS1 could be used to predict the possibility of TIS screw fixation. If the BH exceeds 20.6mm or HDS1 is less than 18.6mm, TIS screw fixation for S1 should not be undertaken because of narrowed SZ.
More Related Videos
12:25C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
Published on: September 16, 2022
09:07An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model
Published on: May 31, 2017