Novel AlN/Pt/ZnO Electrode for High Temperature SAW Sensors
Xingpeng Liu1, Bin Peng2, Wanli Zhang3
1State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China, Chengdu 610054, China. tadyliu@outlook.com.
Abstract:
In order to develop a film electrode for the surface acoustic wave (SAW) devices working in high temperature, harsh environments, novel AlN/Pt/ZnO multilayers were prepared using pulsed laser deposition (PLD) systems on langasite (LGS) substrates. The AlN film was used as a protective layer and the ZnO buffer layer was introduced to improve the crystal quality of Pt films. The results show that the resistances of Pt and AlN/Pt film electrodes violently increase above 600 °C and 800 °C, respectively, while the resistances of AlN/Pt/ZnO electrodes have more stable electrical resistance from room temperature to 1000 °C. The AlN/Pt/ZnO electrode, where the ZnO film was deposited at 600 °C, has the best temperature stability and can steadily work for 4 h at 1000 °C. The mechanism underlying the stable resistance of the AlN/Pt/ZnO electrode at a high temperature was investigated by analyzing the microstructure of the prepared samples. The proposed AlN/Pt/ZnO film electrode has great potential for applications in high temperature SAW sensors.
More Related Videos
06:39Aerosol-assisted Chemical Vapor Deposition of Metal Oxide Structures: Zinc Oxide Rods
Published on: September 14, 2017
08:18Synthesis and Characterization of High c-axis ZnO Thin Film by Plasma Enhanced Chemical Vapor Deposition System and its UV Photodetector Application
Published on: October 3, 2015
Related Concept Videos
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...