Abstract:
The aim of this study is to present and evaluate a multiparametric and multi-modality imaging protocol applied to brain tumours and investigate correlations between these different imaging measures. In particular, we describe a method for rapid, non-invasive, quantitative imaging of water content of brain tissue, based on a single multiple-echo gradient-echo (mGRE) acquisition. We include in the processing a method for noise reduction of the multi-contrast data based on Principal Component Analysis (PCA). Noise reduction is a key ingredient to obtaining high-precision water content and transverse relaxation T2∗ values. The quantitative method is applied to brain tumour patients in a hybrid MR-PET environment. Active tumour tissue is identified by means of FET-PET; oedema, white and grey-matter segmentation is performed based on MRI contrasts. Water content information is not only relevant by itself, but also as a basis for correlations with other quantitative measures of water behaviour in tissue and interpreting the microenvironment of water. Water content in active tumour tissue (84%) and oedema (79%) regions is found to be higher than that of normal WM (69%) and close to that of normal GM (83%). Consistent with literature reports, mean kurtosis is measured to be lower in tumour and oedema regions than in normal WM and GM, whereas mean diffusivity is increased. Voxel-based correlations between water content and diffusion indices obtained with diffusion kurtosis tensor imaging, and between quantitative MRI and FET-PET are reported for 8 brain tumour patients. The effective transverse relaxation time T2∗ is found to be the MR parameter showing the strongest correlations with other MR indices derived here and with FET-PET.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...
Magnetic Resonance Imaging