METHODS FOR ESTIMATION OF BLOOD GLUCOSE : A COMPARATIVE EVALUATION.

Vivek N Ambade1, Y V Sharma2, B L Somani3

  • 1Scientist C, Armed Forces Medical College, Pune 411040.

Medical Journal, Armed Forces India
|August 5, 2017
PubMed
Summary

The GOD-POD method for blood glucose testing is accurate and precise, outperforming older methods like Modified Folin Wu and O-Toluidine. This makes it ideal for routine clinical chemistry analysis.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Biochemical Alteration in Serum Alpha-1 Antitrypsin Levels in Patients with Chronic Obstructive Pulmonary Disease.

Indian journal of clinical biochemistry : IJCB·2025
Same author

PORPHOBILINOGEN DEAMINASE AND ADENOSINE DEAMINASE ACTIVITY AS A POSSIBLE DIAGNOSTIC AID IN LYMPHATIC LEUKEMIAS.

Medical journal, Armed Forces India·2017
Same author

LIPID PROFILE IN NORMAL HEALTHY CHILDREN.

Medical journal, Armed Forces India·2017
Same author

MODIFIED BROMOPHENOL BLUE DYE BINDING METHOD FOR QUANTITATION OF MICROALBUMINURIA IN DIABETES MELLITUS.

Medical journal, Armed Forces India·2017
Same author

CLINICAL UTILITY OF BETA 2 MICROGLOBULIN MEASUREMENT.

Medical journal, Armed Forces India·2017
Same author

Serum Ornithine Carbamoyl Transferase as a Surrogate Marker in Malaria.

Medical journal, Armed Forces India·2016

Area of Science:

  • Clinical Chemistry
  • Biomedical Analysis

Background:

  • Blood glucose measurement is a critical clinical chemistry parameter.
  • Traditional methods like Modified Folin Wu and O-Toluidine are commonly used but have limitations.

Purpose of the Study:

  • To compare the accuracy and precision of Modified Folin Wu, O-Toluidine, and GOD-POD methods against the reference UV-Hexokinase method for blood glucose analysis.

Main Methods:

  • Comparative study involving Modified Folin Wu, O-Toluidine, GOD-POD, and UV-Hexokinase methods.
  • Evaluation of linearity, precision (Coefficient of Variation - CV), and accuracy (Average Deviation).

Main Results:

  • Modified Folin Wu and O-Toluidine methods exhibited upward deviation, imprecision (CVs 4.9%-3.5% and 6%-5.8%), and inaccuracy (Avg. deviation 5.76% and 10.68%).
Keywords:
Blood glucoseDiabetes mellitusGlucose oxidase

More Related Videos

A Method for Manipulating Blood Glucose and Measuring Resulting Changes in Cognitive Accessibility of Target Stimuli
08:01

A Method for Manipulating Blood Glucose and Measuring Resulting Changes in Cognitive Accessibility of Target Stimuli

Published on: August 12, 2016

9.5K
Low-Cost, Volume-Controlled Dipstick Urinalysis for Home-Testing
06:55

Low-Cost, Volume-Controlled Dipstick Urinalysis for Home-Testing

Published on: May 8, 2021

6.3K

Related Experiment Videos

Last Updated: Feb 25, 2026

Bergmeyer Glucose Quantification for Microbiological Samples
07:23

Bergmeyer Glucose Quantification for Microbiological Samples

Published on: January 17, 2025

1.3K
A Method for Manipulating Blood Glucose and Measuring Resulting Changes in Cognitive Accessibility of Target Stimuli
08:01

A Method for Manipulating Blood Glucose and Measuring Resulting Changes in Cognitive Accessibility of Target Stimuli

Published on: August 12, 2016

9.5K
Low-Cost, Volume-Controlled Dipstick Urinalysis for Home-Testing
06:55

Low-Cost, Volume-Controlled Dipstick Urinalysis for Home-Testing

Published on: May 8, 2021

6.3K
  • The GOD-POD method demonstrated linearity up to 500 mg/dl, good precision (CV 0.7%-1.4%), and high accuracy (Avg. deviation -0.97%).
  • Conclusions:

    • The GOD-POD method is a superior alternative for routine blood glucose analysis due to its accuracy, precision, simplicity, and cost-effectiveness.
    • The GOD-POD method is recommended for adoption in routine clinical chemistry laboratories.