Legionella pneumophila LPS to evaluate urinary antigen tests
Anne-Gaëlle Ranc1, Margot Carpentier2, Laëtitia Beraud2
1Hospices Civils de Lyon, Centre, National de Référence des Légionelles, France; CIRI, Centre International de Recherche en Infectiologie, Université de Lyon, Lyon, France; INSERM U1111, Lyon, France Ecole Normale Supérieure de Lyon, Lyon, France; Université Lyon 1, Lyon, France; CNRS, UMR 5308, Lyon, France.
Three urinary antigen tests for Legionella pneumophila (Lp) were evaluated. Detection limits varied by Lp serogroup and strain type, impacting diagnostic accuracy for Legionnaires' disease.
Area of Science:
- Clinical microbiology
- Diagnostic test evaluation
- Infectious disease diagnostics
Background:
- Legionnaires' disease is a severe pneumonia caused by Legionella pneumophila.
- Urinary antigen tests are crucial for rapid Legionnaires' disease diagnosis.
- Performance variations in these tests necessitate thorough evaluation.
Purpose of the Study:
- To compare the diagnostic performance of three urinary antigen tests for Legionella pneumophila.
- To assess the impact of Legionella pneumophila serogroup and strain type on test sensitivity.
Main Methods:
- Purified Legionella pneumophila (Lp) lipopolysaccharide (LPS) was used to determine the limits of detection (LOD) for three urinary antigen tests.
- Tests evaluated included Sofia®FIA, Binax®EIA, and BinaxNOW®.
- LPS from Lp serogroup 1 (Pontiac and non-Pontiac strains) and other Lp serogroups were utilized.
Main Results:
- For Lp serogroup 1, Sofia®FIA and Binax®EIA demonstrated similar limits of detection, while BinaxNOW® had a lower limit of detection.
- All tested urinary antigen tests showed a higher limit of detection for LPS from non-Pontiac strains compared to Pontiac strains.
- The limits of detection were variable across different Lp serogroups.
Conclusions:
- Urinary antigen test performance for Legionella pneumophila varies significantly based on serogroup and strain type.
- These findings highlight the need for improved diagnostic accuracy and broader serogroup coverage in Legionnaires' disease testing.
- Further research is warranted to optimize Legionella urinary antigen detection methods.