Related Experiment Video
Updated: Feb 25, 2026

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Initial Clinical Experiences With Novel Diagonal ECLS System in Pediatric Cardiac Patients
Yildiz Okan1, Haydin Sertac1, Ozturk Erkut2
1Department of Pediatric Cardiovascular Surgery, Istanbul Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Education and Research Hospital, Istanbul, Turkey.
Abstract:
Extracorporeal life support (ECLS) provides mechanical support following cardiac surgery when respiratory or cardiac failure occurs. The aim of this study was to analyze the safety and feasibility of the Medos Deltastream diagonal pump (DP3) ECLS system in pediatric cardiac patients. We described the technical considerations and risk factors related to the survival outcomes in 102 pediatric cardiac patients who received ECLS support between March 2011 and April 2016. We switched from the DP2 system, which was used for the initial 25 patients, to the DP3 system after November 2012. The DP3 was then used in a consecutive series of 77 patients (4.5% of all pediatric patients who underwent congenital heart surgery during the same time period). The patients' median age was 90 days (range: 2 days-12 years), while their median weight was 4 kg (range: 2.1-40 kg). Fifty four patients (70%) were weaned off ECLS, while 28 patients (36.3%) were successfully discharged from the hospital by means of the DP3 system. The median ECLS duration for survivors was 8.2 days (range: 4-14.5 days). The ECLS indications, durations, and initiation times had no statistical significance in terms of survival. Renal, hemorrhagic, and neurologic complications were all associated with decreased hospital discharge rates (P = 0.003, P = 0.045, and P < 0.001 respectively). Higher lactate levels (P = 0.009) and longer duration for normalization (P < 0.001) were both associated to failure to wean off ECLS support and, hence, to hospital deaths. The weaning rate was 36% prior to November 2012. It increased to 70.3% after that time (P = 0.009). The mechanical complication rate was 9% with the DP3 system and 32% with the DP2, which was statistically significant (P = 0.009). Additionally, the lactate levels were higher and decreased more slowly in the patients supported by the DP2. As a result of the shift to the DP3 system, a revised ECLS protocol, and increased ECLS experience, a significant improvement was observed in our clinical outcomes. The results of this study suggested that the combination of a DP3 pump and a Hilite oxygenator in pediatric ECLS circuits may improve durability and reduce circuit-induced complications.
More Related Videos
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
08:42Cox-Maze IV Procedure Concomitant with Valvular Surgery In Situs Inversus Dextrocardia: A Single-Center Experience in China