Related Experiment Video
Updated: Feb 25, 2026

Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages
Published on: March 24, 2023
Selective patient experience with the Blom-Singer Dual Valve voice prosthesis
Ben Brownlee1, Saniya Ahmad1, Tracy Grammer1
1Department of Otorhinolaryngology, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, U.S.A.
Objectives/Hypothesis:
This study compares the overall durability, phonation effort, and speech quality achieved by the Blom-Singer Dual Valve prosthesis to the same characteristics achieved by the single-valve prosthesis used in a select population of total laryngectomy patients who have demonstrated single-valve prosthesis failure within 3 months of placement.
Study Design:
Prospective phase IV study.
Methods:
Fourteen patients who had previously experienced early valve failure using a single-valve prosthesis had a Dual Valve placed by a speech language pathologist. A total of seventeen Dual Valves were inserted during routine clinical visits for valve replacement. Time intervals from insertion to replacement of the Dual Valve, as well as the average lifespan of patients' three previous single valves were collected. Subjective, categorical responses to speech quality and phonation effort for the Dual Valve compared to the single valve were collected on a questionnaire upon failure of the device.
Results:
The mean duration of the single valve was 60 days, with a median of 51 days, whereas the mean duration of the Dual Valve was 164 days, with a median duration of 84 days. Both sets of data were statistically significant, with a P value of .0131. Valve life was increased in 86% of patients, with 43% experiencing greater than 150 days improvement in valve duration when using the Dual Valve. Phonation effort was increased in 14% of patients, and speech quality was not significantly affected in any patients.
Conclusions:
In this select population, the Dual Valve offers improved durability over the single valve without sacrificing speech quality, making it a preferred prosthesis option for patients experiencing single-valve failure in less than 3 months.
Level Of Evidence:
4. Laryngoscope, 128:422-426, 2018.
Related Concept Videos
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Tracheostomy Suctioning II: Procedure
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...