Third CoreValve™ insertion for treatment of a severe paravalvular leak after a failed valve-in-valve procedure
Rodrigo Estévez-Loureiro1, Carlos Cuellas1, Javier Gualis2
1Department of Cardiology, Complejo Asistencial Universitario de León, León, Spain.
Abstract:
An 83-year-old high-risk gentleman diagnosed with severe symptomatic aortic stenosis was scheduled for TAVR. A 31 mm CoreValve was implanted but severe paravalvular leak was noted. A valve-in-valve procedure was performed. However, the valve frame was partially dislodged into de ascending aorta. We report our strategy to solve this severe leak after a failed valve-in-valve procedure.