Video Movement Analysis Using Smartphones ViMAS: A Pilot Study
Published on: March 14, 2017
Validity of the Digital Inclinometer and iPhone When Measuring Thoracic Spine Rotation
Jonathan Bucke1, Simon Spencer1, Louise Fawcett1
1English Institute of Sport, Shropshire, United Kingdom.
Context:
Spinal axial rotation is required for many functional and sporting activities. Eighty percent of axial rotation occurs in the thoracic spine. Existing measures of thoracic spine rotation commonly involve laboratory equipment, use a seated position, and include lumbar motion. A simple performance-based outcome measure would allow clinicians to evaluate isolated thoracic spine rotation. Currently, no valid measure exists.
Objective:
To explore the criterion and concurrent validity of a digital inclinometer (DI) and iPhone Clinometer app (iPhone) for measuring thoracic spine rotation using the heel-sit position.
Design:
Controlled laboratory study.
Setting:
University laboratory.
Patients Or Other Participants:
A total of 23 asymptomatic healthy participants (14 men, 9 women; age = 25.82 ± 4.28 years, height = 170.26 ± 8.01 cm, mass = 67.50 ± 9.46 kg, body mass index = 23.26 ± 2.79) were recruited from a student population.
Main Outcome Measure(S):
We took DI and iPhone measurements of thoracic spine rotation in the heel-sit position concurrently with dual-motion analysis (laboratory measure) and ultrasound imaging of the underlying bony tissue motion (reference standard). To determine the criterion and concurrent validity, we used the Pearson product moment correlation coefficient (r, 2 tailed) and Bland-Altman plots.
Results:
The DI (r = 0.88, P < .001) and iPhone (r = 0.88, P < .001) demonstrated strong criterion validity. Both also had strong concurrent validity (r = 0.98, P < .001). Bland-Altman plots illustrated mean differences of 5.82° (95% confidence interval [CI] = 20.37°, -8.73°) and 4.94° (95% CI = 19.23°, -9.35°) between the DI and iPhone, respectively, and the reference standard and 0.87° (95% CI = 6.79°, -5.05°) between the DI and iPhone.
Conclusions:
The DI and iPhone provided valid measures of thoracic spine rotation in the heel-sit position. Both can be used in clinical practice to assess thoracic spine rotation, which may be valuable when evaluating thoracic dysfunction.
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...