Effectiveness of Florbetapir PET Imaging in Changing Patient Management
Michael J Pontecorvo1, Andrew Siderowf, Bruno Dubois
1Avid Radiopharmaceuticals (a wholly owned subsidiary of Eli Lilly and Company), Philadelphia, PA, USA.
Aims:
To evaluate the impact of amyloid PET imaging on diagnosis and patient management in a multicenter, randomized, controlled study.
Methods:
Physicians identified patients seeking a diagnosis for mild cognitive impairment or dementia, possibly due to Alzheimer disease (AD), and recorded a working diagnosis and a management plan. The patients underwent florbetapir PET scanning and were randomized to either immediate or delayed (1-year) feedback regarding amyloid status. At the 3-month visit, the physician updated the diagnosis and recorded a summary of the actual patient management since the post-scan visit. The study examined the impact of immediate versus delayed feedback on patient diagnosis/management at 3 and 12 months.
Results:
A total of 618 subjects were randomized (1:1) to immediate or delayed feedback arms, and 602 subjects completed the 3-month primary endpoint visit. A higher proportion of patients in the immediate feedback arm showed a change in diagnosis compared to the controls (32.6 vs. 6.4%; p = 0.0001). Similarly, a higher proportion of patients receiving immediate feedback had a change in management plan (68 vs. 55.5%; p < 0.002), mainly driven by changes in AD medication. Specifically, acetylcholinesterase inhibitors were prescribed to 67% of the amyloid-positive and 27% of the amyloid-negative subjects in the information group compared with 56 and 43%, respectively, in the control group (p < 0.0001). These between-group differences persisted until the 12-month visit.
Conclusion:
Knowledge of the amyloid status affects the diagnosis and alters patient management.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...