Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
Night-time blood pressure and pulse wave velocity in dialysis patients
Xiurong Li1, Qingbo Jiang2, Wenhui Wu1
1Department of Hemodialysis, The Third Affiliated Hospital of Soochow University, Changzhou, China.
Background:
Ambulatory blood pressure (ABP) monitoring and carotid-femoral pulse wave velocity (cfPWV) provide important cardiovascular risk information for dialysis patients. This study aims to evaluate the risk factors of cfPWV and the associations between ambulatory blood pressure, especially night-time blood pressure and cfPWV.
Methods:
We conducted a cross-sectional study in patients on maintenance hemodialysis. ABP and cfPWV were measured on a midweek interdialytic day. Associations were determined using Pearson's correlation analysis and multiple stepwise regression model.
Results:
Systolic BPs and pulse pressures, but not diastolic BPs, were significantly and positively associated with cfPWV. In a stepwise regression model, age, diabetes mellitus and all-period systolic BP were independently associated with cfPWV. When day-time and night-time BPs were included in the analysis, respectively, only night-time systolic BP and age remained as independently associated with cfPWV.
Conclusion:
Ambulatory BPs are potent associates of cfPWV and night-time systolic BP, rather than day-time BPs, is an independently predictor of cfPWV. Our results support the view that controlling of nocturnal hypertension provides a unique cardiovascular protection effect.
Related Concept Videos
Hemodialysis III: Nursing Management
Hemodialysis II: Procedure and Complications
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.