Related Experiment Video
Updated: Feb 25, 2026

Author Spotlight: A Novel 3D-Printed Titanium Implant for Minimally Invasive Treatment of Hip Dysplasia in Young Dogs
Published on: April 19, 2024
Added value of 18F-FDG PET/CT in diagnosing infected hip prosthesis
Robert M Kwee1,2, Wouter Am Broos1, Boudewijn Brans1
11 Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands.
Abstract:
Background The diagnosis of infected hip prosthesis is frequently not straightforward yet very important as it changes treatment. Purpose To retrospectively investigate the added value of 18F-FDG PET/CT to conventional tests including radiography, erythrocyte sedimentation rate (ESR)/C-reactive protein (CRP) testing, and joint aspiration, in diagnosing infected hip prosthesis. Material and Methods Seventy-eight hip prostheses of 78 patients (55% men; mean age = 66.5 years; age range = 30-85 years) with non-specific clinical presentation, i.e. no abscess or sinus tract communicating with the joint space at clinical examination, were analyzed. Cultures of intra-articular fluid and peri-implant tissues after revision surgery or clinical follow-up ≥6 months served as gold standard. Areas under the receiver operating characteristic curves (AUCs) of radiography, ESR/CRP testing, aspiration culture, and white blood cell (WBC) count without and with the addition of 18F-FDG PET/CT were compared. Results The addition of 18F-FDG PET/CT increased AUCs: for radiography with 0.212, P = 0.001; for ESR/CRP testing with 0.076, P = 0.072; for aspiration culture with 0.126, P = 0.032; and for aspiration WBC count with 0.191, P = 0.035. Conclusion This study shows that 18F-FDG PET/CT adds to individual conventional tests in diagnosing infected hip prosthesis. It may improve the preoperative planning and should therefore be considered in the diagnostic work-up. Future studies should define the exact place of 18F-FDG PET/CT in the diagnostic work-up of periprosthetic joint infection.
More Related Videos
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT
Published on: May 2, 2012
07:45The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET