Cortrak tube placement part 2: guidance to avoid misplacement is inadequate
Stephen J Taylor1, Rowan Clemente2, Kaylee Allan2
1Research Dietitian, Department of Nutrition and Dietetics, Southmead Hospital, Bristol.
Abstract:
Electromagnetic (EM)-guided tube placement has been successfully used to pre-empt lung misplacement, but undetected misplacements continue to occur. The authors conducted an audit to investigate whether official Cortrak or local guidance enabled differentiation of gastrointestinal (GI) from lung traces. X-ray, pH or an EM trace beyond the gastric body were used to independently confirm gastric position. The authors undertook 596 nasointestinal (NI) tube placements, of which 361 were primary GI placements and 41 lung misplacements. Official guidance that in GI traces a midline deviation is absent cannot differentiate GI from lung traces because deviation is common in both. However, when comparing a trace in the same patient, midline deviation during lung misplacement always occurred >18 cm above the horizontal line compared with only 33% of the subsequent GI deviation (p<0.0001). Official guidance could lead to aborted GI placements or undetected lung placements. EM-guided placement must have an expert-led understanding of the 3D trace pattern, artefact correction and appraised practical experience differentiating GI from lung placement. The authors invite Halyard Health to update guidance in view of these findings.
More Related Videos
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
07:47The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...