A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
Comparison of Two Creatinine Based Equations for Routine Estimation of GFR in a Speciality Clinic for Diabetes
Satyavani Kumpatla1, Anju Soni2, Vijay Viswanathan3
1Lab Director.
Objective:
To compare the bias, absolute bias, precision and accuracies between the equations, viz., CKD-EPI (Scr), CKD-EPI (Scys) and MDRD in Indian patients with type 2 diabetes.
Methods:
198 patients who underwent 24 h urinary collection for assessing kidney function between November 2014-January 2015 were included. Cohen's κ coefficient, Bland-Altman plot were calculated between estimated kidney function equations, and bias, precision, accuracies was calculated between the formulae.
Results:
The mean eGFR based on MDRD, CKD-EPI (Scr) and CKD-EPI (Scys) equations were 64.5±21.9, 70.2±25.1 and 74.7±31.0 ml/min/ 1.73m2 respectively. The overall mean absolute bias was smallest for MDRD vs CKD EPI (Scr). The precision was also least for MDRD vs CKD EPI (Scr) indicating that the agreement between these equations is consistent for the range of values. MDRD vs CKD EPI (Scr) had the highest accuracy in comparison to other compared formula. The performance between MDRD versus CKD EPI (Scys) was different. There was a good agreement between MDRD and CKD EPI (Scr).in both stage 3 and stage 4 CKD. The MDRD vs CKD EPI (Scr) classified 72.2% of the patients correctly.
Conclusions:
In conclusion, there was a good agreement between CKD-EPI (Scr) and MDRD equations. CKD-EPI equation based on creatinine estimation is widely accepted method and clinicians may use this equation in routine clinical practice to assess kidney function among patients with type 2 diabetes.
Related Concept Videos
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...