Related Experiment Videos
Core Temperature Monitoring in Obstetric Spinal Anesthesia Using an Ingestible Telemetric Sensor
Leon du Toit1, Dominique van Dyk1, Ross Hofmeyr1
1From the Department of Anaesthesia and Perioperative Medicine, University of Cape Town, Cape Town, South Africa.
Background:
Perioperative hypothermia may affect maternal and neonatal outcomes after obstetric spinal anesthesia. Core temperature is often poorly monitored during spinal anesthesia, due to the lack of an accurate noninvasive core temperature monitor. The aim of this study was to describe core temperature changes and temperature recovery during spinal anesthesia for elective cesarean delivery. We expected that obstetric spinal anesthesia would be associated with a clinically relevant thermoregulatory insult (core temperature decrease >1.0°C).
Methods:
A descriptive study was conducted in 28 women. An ingestible telemetric temperature sensor was used to record core temperature over time (measured every 10 seconds). The primary outcome was the maximum core temperature decrease after spinal anesthetic injection. The secondary outcomes were lowest absolute core temperature, time to lowest temperature, time to recovery of core temperature, hypothermic exposure (degree-hours below 37.0°C), and the time-weighted hypothermic exposure (median number of degrees below 37.0°C per hour). Basic descriptive statistics, median spline smooth, and integration of the area below the 37.0°C line of the temperature-over-time curve were utilized to analyze the data.
Results:
Intestinal temperature decreased by a mean (standard deviation) of 1.30°C (0.31); 99% confidence interval (CI), 1.14 to 1.46 after spinal anesthetic injection. The median (interquartile range [IQR]) time to temperature nadir was 0.96 (0.73-1.32) hours (95% CI, 0.88-1.22). Fourteen of the 28 participants experienced intestinal temperatures below 36.0°C after spinal injection. Temperature was monitored for a minimum of 8 hours after spinal injection. In 8 of 28 participants, intestinal temperature did not recover to baseline during the monitored period. A median (IQR) of 4.59 (3.38-5.92) hours (95% CI, 3.45-5.90) was required for recovery to baseline intestinal temperature in the remaining 20 patients. Participants experienced a median (IQR) of 1.97 (1.00-2.68) degree-hours of hypothermic exposure (95% CI, 1.23-2.45). The median (IQR) number of degrees below 37.0°C per hour was 0.45 (0.35-0.60) (95% CI, 0.36-0.58).
Conclusions:
During cesarean delivery under spinal anesthesia, women experienced a rapid decrease in core temperature. Using an intestinal telemetric sensor, the perioperative thermal insult and recovery were documented with high resolution. Fifty percent of participants in this study became hypothermic. Although the surgical procedure is typically of short duration, women undergoing spinal anesthesia for cesarean delivery experience significant hypothermic exposure and compromised thermoregulation for several hours.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...