Related Experiment Video
Updated: Feb 24, 2026

Measurement of the Hepatic Venous Pressure Gradient and Transjugular Liver Biopsy
Published on: June 18, 2020
The Best Single Measurement for Assessing Splenomegaly in Patients with Cirrhotic Liver Morphology
Zachary Nuffer1, Thomas Marini2, Andrey Rupasov1
1Department of Imaging Sciences, University of Rochester Medical Center, 601 Elmwood Ave, Box 648, Rochester, NY 14642.
Rationale And Objectives:
There is little agreement within the radiology literature as to the best single measurement for assessing splenomegaly. In this study, we evaluate the correlation of multiple unidirectional measurements of the spleen with splenic volume in patients with cirrhotic liver morphology on computed tomography (CT).
Materials And Methods:
Splenic volume was retrospectively calculated from CT examinations of 179 adult patients, 47 of whom were approved as renal donors, and 132 of whom were referred for various other indications, and were found to have cirrhotic liver morphology on CT. Seven unidimensional measurements (long-axis, cranial-caudal, width, and four measures of thickness) of each spleen were evaluated to identify which most closely correlated with the calculated volume.
Results:
The splenic width had the best correlation with splenic volume for mild-to-moderate splenomegaly, and the splenic cranial-caudal measurement had the best correlation with splenic volume for massive splenomegaly. Receiver operating characteristic analysis demonstrates that a splenic width measurement of approximately 10.5 cm has a sensitivity of 89% and a specificity of 78% for mild-to-moderate splenomegaly, and a cranial-caudal measurement of 14.6 cm has a sensitivity of 92% and a specificity of 91% for massive splenomegaly.
Conclusions:
A splenic width threshold of 10.5 cm is the most sensitive (89%) and specific (78%) single measurement for mild-to-moderate splenomegaly in patients with cirrhotic liver morphology, whereas a cranial-caudal height threshold of 14.6 cm is the most sensitive (92%) and specific (91%) single measurement for massive splenomegaly.
More Related Videos
04:00Laparoscopic Splenectomy with Pericardial Devascularization for Hypersplenism and Esophageal Variceal Hemorrhage Due to Portal Hypertension
Published on: November 15, 2024
04:40Bloodless Laparoscopic Partial Splenectomy Assisted by Bipolar Radiofrequency Excision Hemostatic Device
Published on: November 4, 2022
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...
Assessment of the Abdomen III: Palpation