Related Experiment Video
Updated: Feb 24, 2026

Electrophoretic Separation of Proteins
Published on: June 12, 2008
Cationic ionic liquid surfactant-polyacrylamide gel electrophoresis for enhanced separation of acidic and basic
Punprabhashi Vidanapathirana1, Farhana Hasan1, Kaitlyn Mussio1
1Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, United States.
Abstract:
Cationic ionic liquids-based surfactants (ILS), such as 4-methyl pyridinium bromide (CnPBr, where n=4,6,8), were used in preparation of polyacrylamide gels, sample buffer, and running buffer for cationic ILS polyacrylamide gel electrophoresis (ILS-PAGE). These ILS are liquids in the pure state and were selected for improved separation of ribonuclease b (Rib b) glycoforms in a single step and a protein mixture containing bovine serum albumin (BSA, pI-4.8, 66.5kDa), ovalbumin (Ova, pI-4.6, 44.3kDa), α-chymotrypsinogen (α-Chy, pI-8.8, 25.7kDa), myoglobin (Myo, pI-6.8, 16.9kDa), and cytochrome c (Cyt c, pI-10.0, 12.3kDa). Results acquired for Rib b glycoform separation by use of ILS were compared with conventional non-ILS surfactants-PAGE: sodium dodecylsulfate (SDS)-PAGE, cetyltrimethylammonium bromide (CTAB)-PAGE, and benzyldimethyl-n-hexadecylammonium chloride (16-BAC)-PAGE. A single protein band was observed with relatively short migration time in all the conventional PAGE techniques tested. In contrast, ILS-PAGE showed multiple bands with two distinct bands for Rib b protein. The two distinct bands of Rib b from ILS-PAGE were further analyzed using MALDI-MS. Examination of MALDI-MS spectral data revealed the presence of Rib b glycoforms. Furthermore, a two-dimensional isoelectric focusing (IEF)/SDS-PAGE map of Rib b protein revealed negative charge heterogeneity on the protein, which is a common observation for glycoproteins. This overall discovery greatly enhances the capability of using cationic ILS-PAGE for Rib b protein separation. Among all ILS tested, excellent protein separations were observed using C4PBr ILS at concentrations of 0.05% (w/v) in polyacrylamide gels, 0.01% (w/v) in protein sample buffer, and 0.1% (w/v) in running buffer. Under these optimum conditions, all other tested proteins were separated as sharp bands with good resolution.
More Related Videos
12:03Blue Native Polyacrylamide Gel Electrophoresis BN-PAGE for Analysis of Multiprotein Complexes from Cellular Lysates
Published on: February 24, 2011
09:57Separation of Bioactive Small Molecules, Peptides from Natural Sources and Proteins from Microbes by Preparative Isoelectric Focusing IEF Method
Published on: June 14, 2020
Related Concept Videos
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...