Related Experiment Video
Updated: Feb 24, 2026

Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Mathematical modelling and evaluation of performance of cuboid packed-bed devices for chromatographic separations
1Department of Chemical Engineering, McMaster University, 1280 Main Street West Hamilton, Ontario, L8S 4L7, Canada.
Abstract:
In a recent paper, box-shaped or cuboid packed bed devices have been proposed as alternative to columns for chromatographic separations. We first propose a mathematical model for residence time distribution in such devices. Based on it, we examine factors likely to affect separation performance, and verify the predictions of our mathematical model by conducting tracer experiments. We then compare the performance of two commercial columns with their respective equivalent cuboid packed-bed devices, i.e. containing the same chromatographic media, and having the same bed-height and bed-volume. Parameters compared include the number of theoretical plates, attributes of flow-through and eluted protein peaks, and resolution in model binary protein separations. For each of these metrics examined, the cuboid packed-bed device outperformed its equivalent commercial column. Other potential advantages likely to be gained from using a cuboid packed-bed instead of a column are elucidated.
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...