Three-dimensional wound mapping software compared to expert opinion in determining wound area.
E Farrar1, O Pujji2, S Jeffery3
1Burns & Plastic Surgery, Queen Elizabeth Hospital Birmingham, United Kingdom.
Burns : Journal of the International Society for Burn Injuries
|August 13, 2017
Summary
A 3D camera system using WoundCare Lite software accurately estimates burn size on mannequins, showing excellent agreement with expert assessments. This technology could improve burn wound assessment in clinical settings.
Area of Science:
- Medical Technology
- Burn Management
- Wound Assessment
Background:
- Accurate total body surface area (TBSA) burn estimation is critical for fluid resuscitation and preventing complications.
- Current TBSA estimation methods lack a universally accepted gold standard.
- New technologies are continuously evaluated for burn wound and scar assessment.
Purpose of the Study:
- To compare TBSA% burn estimation using a 3D camera (Panasonic FZ-M1 Toughpad with WoundCare Lite) against expert opinion.
- To evaluate the accuracy and reliability of a novel 3D photographic method for burn assessment.
Main Methods:
- Two life-sized mannequins (adult and child) were used to simulate realistic burn patterns.
- Burns were measured using the 3D camera system before expert assessment.
- Burns doctors estimated the TBSA% for 10 adult and 8 child simulated burns.
Main Results:
- The 3D camera system estimated burn sizes ranging from 0.42% to 18.23% TBSA.
- Burn TBSA assessments between the 3D camera and specialist opinions showed excellent agreement (ICC = 0.985).
- A median of 3 assessors evaluated each burn, with a range of 2 to 8 assessors.
Conclusions:
- The WoundCare Lite software with the Panasonic FZ-M1 Toughpad 3D camera demonstrates strong concordance with expert burn TBSA% estimation on mannequins.
- Further research is required to validate this 3D imaging technology for acute burn assessment in patients.