Assessment of advanced hepatic MR elastography methods for susceptibility artifact suppression in clinical patients

Jin Wang1,2, Kevin J Glaser2, Tianhui Zhang1

  • 1Department of Radiology, Third Affiliated Hospital, Sun Yat-Sen University (SYSU), Guangzhou, Guangdong, P.R China.

Abstract

Insights

Spin-echo (SE) magnetic resonance elastography (MRE) sequences demonstrate superior success rates and image quality compared to gradient-recalled echo (GRE) MRE for liver fibrosis staging. These findings highlight SE MRE as a more effective technique in clinical hepatic imaging.

Area of Science:

  • Medical Imaging
  • Hepatology
  • Biophysics

Background:

  • Liver fibrosis staging is crucial for patient management.
  • Magnetic resonance elastography (MRE) is an emerging non-invasive technique for assessing liver stiffness.
  • Liver iron concentration can potentially affect MRE accuracy.

Purpose of the Study:

  • To compare the efficacy of standard 2D gradient-recalled echo (GRE) and four spin-echo (SE) MRE sequences.
  • To evaluate success rate, image quality, and fibrosis staging ability across different MRE sequences.
  • To assess the impact of liver iron concentration on MRE performance.

Main Methods:

  • 3T MRE examinations were performed on 332 patients, with 136 undergoing all five MRE techniques.
  • Liver stiffness, region of interest area, image quality, and success rates were compared.
  • Diagnostic performance for fibrosis staging was assessed using receiver operating characteristic curves (AUCs).

Main Results:

  • SE MRE sequences exhibited significantly higher success rates (99.1-100%) than GRE MRE (85.3%).
  • No significant differences were found in AUCs for discriminating advanced fibrosis among the five sequences.
  • Liver iron concentration (R2*) and BMI significantly affected success rates and image quality in specific MRE sequences.

Conclusions:

  • All five MRE techniques demonstrated good performance in staging liver fibrosis.
  • SE MRE sequences offer higher success rates and superior image quality compared to GRE MRE in 3T hepatic imaging.
  • SE MRE is a more reliable technique for non-invasive liver fibrosis assessment.