Related Experiment Video
Updated: Feb 24, 2026

Measurement of Spatial Stability in Precision Grip
Published on: June 4, 2020
Investigation of index finger triggering force using a cadaver experiment: Effects of trigger grip span, contact
Joonho Chang1, Andris Freivalds1, Neil A Sharkey2
1Department of Industrial and Manufacturing Engineering, Pennsylvania State University, University Park, PA 16802, USA.
Abstract:
A cadaver study was conducted to investigate the effects of triggering conditions (trigger grip span, contact location, and internal tendon force) on index finger triggering force and the force efficiency of involved tendons. Eight right human cadaveric hands were employed, and a motion simulator was built to secure and control the specimens. Index finger triggering forces were investigated as a function of different internal tendon forces (flexor digitorum profundus + flexor digitorum superficialis = 40, 70, and 100 N), trigger grip spans (40, 50, and 60 mm), and contact locations between the index finger and a trigger. Triggering forces significantly increased when internal tendon forces increased from 40 to 100 N. Also, trigger grip spans and contact locations had significant effects on triggering forces; maximum triggering forces were found at a 50 mm span and the most proximal contact location. The results revealed that only 10-30% of internal tendon forces were converted to their external triggering forces.