Related Experiment Video
Updated: Feb 24, 2026

Rodent Estrous Cycle Monitoring Utilizing Vaginal Lavage: No Such Thing As a Normal Cycle
Published on: August 30, 2021
Association between ambient temperature and humidity, vaginal temperature, and automatic activity monitoring on
Liam B Polsky1, Augusto M L Madureira2, Eraldo L Drago Filho2
1Applied Animal Biology, Faculty of Land and Food Systems, University of British Columbia, Vancouver, BC, Canada V6T 1Z4.
Abstract:
The objective of this study was to determine the association between ambient temperature and humidity, vaginal temperature, and automated activity monitoring in synchronized cows. Lactating Holstein cows (n = 641; 41.5 ± 9.4 kg of milk/d) were fitted with leg-mounted pedometers, resulting in 843 evaluated activity episodes of estrus. Vaginal temperature was monitored using thermometers attached to an intravaginal device as part of a timed artificial insemination (TAI) protocol; vaginal temperature was recorded every 10 min for 3 d. Ambient temperature and relative humidity were monitored using an external thermometer placed in the center of each pen. Milk production and body condition score (BCS) data were collected at the time of thermometer insertion. All statistical analysis was performed in R (https://www.r-project.org/) using Pearson correlation, analysis of variance, and logistic regression. Heat stress was calculated based on the percentage of time the cow spent with a vaginal temperature ≥39.1°C (PCT39) 9 to 11 d before TAI, and was classified as high (≥22.9%) or low (<22.9%). The mean vaginal temperature was 38.9 ± 0.2°C, and the mean maximum and minimum vaginal temperatures were 39.7 ± 0.5°C and 38.0 ± 0.8°C, respectively, with an average amplitude of 1.71 ± 0.9°C. Mean relative increase (RI) of estrus walking activity was 237.0 ± 160%. Animals with low BCS had a lower RI compared with cows with medium BCS (260.31 ± 17.45% vs. 296.42 ± 6.62%). Cows in early lactation showed lower RI compared with mid- and late-lactation animals (265.40 ± 9.90% vs. 288.36 ± 11.58% vs. 295.75 ± 11.29% for early, mid, and late lactation, respectively). Temperature-humidity index (THI) conditions categorized as low (THI ≤65) were associated with greater RI compared with medium (>65 to <70) and high THI (≥70). We detected no significant effect of PCT39 or milk production on RI, whereas parity exhibited a tendency. Cows that displayed greater RI at estrus had greater pregnancies per artificial insemination (P/AI) than cows with low RI (27 vs. 20%) or no RI (27 vs. 12%). Primiparous cows had greater P/AI than multiparous cows (27 vs. 20%), and cows in early and mid lactation had improved P/AI than those in late lactation (26 vs. 22 vs. 16% for early, mid, and late lactation, respectively). An interaction was observed between PCT39 and THI on P/AI, where a subpopulation of cows with high PCT39 had decreased P/AI under high THI conditions, but no differences in P/AI were observed for high PCT39 cows under medium or low THI conditions (13 vs. 24 vs. 26%). Future research should aim to refine variables related to hyperthermia and to understand the effects of body temperature on estrus expression and pregnancy rates.
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Factors Affecting Body Temperature
Factors may include:
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...

