Purpose:
To evaluate the optimal ventilation mode during thoracoscopic repair (TR) of neonatal congenital diaphragmatic hernia (CDH), we compared high-frequency oscillatory ventilation (HFOV) with conventional mechanical ventilation (CMV).
Methods:
Twenty-three neonatal CDH cases who underwent TR without intraoperative inhalation of nitric oxide at our institution between 2007 and 2016 were reviewed. Patients were initially ventilated with HFOV, which was converted to CMV if the HFOV settings were decreased to FiO2 <0.4, stroke volume <4 mL/kg and mean airway pressure <12 cmH2O. Arterial blood gases in the perioperative period were compared between HFOV and CMV.
Results:
Seventeen patients were ventilated with HFOV (group I), and six patients were ventilated with CMV (group II). Preoperative PaCO2 was significantly higher and pH was significantly lower in group I compared with group II. In both groups I and II, intraoperative PaCO2 increased significantly and pH decreased significantly compared with preoperation. Although intraoperative PaCO2 and pH were not different between the groups, group II showed greater worsening of intraoperative PaCO2 and pH as compared to their respective preoperative values.
Conclusions:
HFOV seems to prevent deterioration of hypercapnia and acidosis to a greater extent than CMV during TR in neonatal cases of CDH, although patients can also be ventilated with CMV.
More Related Videos
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation I: Indication and Settings
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Tracheostomy Suctioning II: Procedure