Related Experiment Video
Updated: Feb 24, 2026

Author Spotlight: Advancing Cardiovascular Imaging - Introducing the Spatially Weighted Calcium Score for Early Disease Detection
Published on: September 22, 2023
Assessment of aortic valve calcium load by multidetector computed tomography. Anatomical validation, impact of
Jamila Boulif1, Bernhard Gerber1, Alisson Slimani1
1Pôle de Recherche Cardiovasculaire, Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain, Avenue Hippocrate 10, 1200 Brussels, Belgium; Divisions of Cardiology and Cardiothoracic Surgery, Cliniques Universitaires Saint-Luc, Avenue Hippocrate 10, 1200 Brussels, Belgium.
Objectives:
To validate aortic valve calcium (AVC) load measurements by multidetector row computed tomography (MDCT), to evaluate the impact of tube potential and slice thickness on AVC scores, to examine the accuracy of AVC load in distinguishing severe from nonsevere aortic stenosis (AS) and to investigate its effectiveness as an alternative diagnosis method when echocardiography remains inconclusive.
Methods:
We prospectively studied 266 consecutive patients with moderate to severe AS who underwent MDCT to measure AVC load and a comprehensive echocardiographic examination to assess AS severity. AVC load was validated against valve weight in 57 patients undergoing aortic valve replacement. The dependence of AVC scores on tube potential and slice thickness was also tested, as well as the relationship between AVC load and echocardiographic criteria of AS severity.
Results:
MDCT Agatston score correlated well with valve weight (r = 0.82, p < 0.001) and hemodynamic indices of AS severity (all p < 0.001). Ex-vivo Agatston scores decreased significantly with increasing tube potential and slice thickness (repeated measures ANOVA p < 0.001). Multivariate analysis identified mean gradient, the indexed effective orifice area, male gender and left ventricular outflow tract cross-sectional area as independent correlates of the in-vivo AVC load.
Conclusions:
MDCT-derived AVC load correlated well with valve weight and hemodynamic indices of AS severity. It also depends on tube potential and slice thickness, thus suggesting that these parameters should be standardized to optimize reproducibility and accuracy.
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

