The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
A randomised trial comparing real-time double-lumen endobronchial tube placement with the Disposcope® with
P T Chen1,2,3, C K Ting1,2, M Y Lee1
1Department of Anesthesiology, Taipei Veterans General Hospital, Taipei, Taiwan, Republic of China.
Abstract:
Double-lumen endobronchial tube placement is challenging. This study compared double-lumen tube placement with the Disposcope® , a wireless videostylet allowing real-time visualisation, with conventional blind placement. Patients undergoing elective thoracic surgery with normal airways requiring one-lung ventilation were randomly allocated into two groups (27 patients in each group). The Disposcope was used to assist left-sided double-lumen tube placement in one group, and conventional blind placement was performed in the control group. Placement in both groups was checked with fibreoptic bronchoscopy. The Disposcope-assisted group had a shorter total mean (SD) placement time (18.6 (2.5) s vs. 21.4 (2.9) s, p < 0.001), laryngoscopy to end of auscultation time (83.4 (3.0) s vs. 93.9 (5.7) s, p < 0.001) and total operation time (130.7 (6.1) s vs. 154.5 (6.3) s, p < 0.001). In the Disposcope-assisted group, the double-lumen tube was inserted in the correct side in all patients (100.0%), whereas in the conventional group, the double-lumen tube was placed in the correct side in 25 (92.6%) patients and in the wrong side in 2 (7.4%) patients; the difference was not significant (p = 0.150). In the Disposcope-assisted group, the double-lumen tube was inserted to the optimal depth in 24 (88.9%) patients, whereas in the conventional group it was inserted to the optimal depth in one (4.0%) patient. The Disposcope increased the success rate of double-lumen tube placement, and shortened the total operation time when compared with standard placement with confirmation using fibreoptic bronchoscopy, and may replace the conventional method.
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Blinding