Casting doubt on the value of assessing the cardiac index in pregnancy
Maya Ram1, Anat Lavie1, Shaul Lev2
1a Department of Obstetrics and Gynecology , Tel Aviv Sourasky Medical Center , Tel Aviv , Israel.
Objectives:
The objective of this study is to assess the reliability of the cardiac index (CI) in healthy pregnant women at term by investigating the correlation between the cardiac output (CO) and the body surface area (BSA) using a novel non-invasive cardiography technique (NICaS™).
Methods:
Sixty-one healthy, normotensive women with a singleton pregnancy at term (≥37 gestational weeks) participated in this prospective observational study between 1/2015 and 6/2015 L. Each woman was assessed for CO by the NICaS™, an impedance device that non-invasively measures the CO and its derivatives. The NICaS™ demonstrated a very good correlation with the gold standard Swan-Ganz catheter. BSA was determined by the Dubois nomogram.
Results:
The mean ± standard deviation maternal age was 34.2 ± 5.3 years, mean height 166 ± 6 cm, and mean body mass index 23.9 ± 4.9 kg/m2. The mean gestational age was 38.8 ± 0.7 weeks. The correlation between the CO and the BSA was poor (Pearson r = 0.254, p < .005).
Conclusions:
The current study demonstrated poor correlation between the CO and the BSA in pregnant women, therefore, making the CI a non-reliable variable for assessing CO in pregnant women. We, therefore, suggest that the CO rather than the CI is the preferred parameter for hemodynamic measurements in this population.
Related Concept Videos
Mitral Valve Prolapse III: Nursing Management
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiomyopathy VI: Nursing Management
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...