Abstract:
Introduction Ventilation with a bag valve mask (BVM) is a challenging but critical skill for airway management in the prehospital setting. Hypothesis Tidal volumes received during single rescuer ventilation with a modified BVM with supplemental external handle will be higher than those delivered using a standard BVM among health care volunteers in a manikin model.
Methods:
This study was a randomized crossover trial of adult health care providers performing ventilation on a manikin. Investigators randomized participants to perform single rescuer ventilation, first using either a BVM modified by addition of a supplemental external handle or a standard unmodified BVM (Spur II BVM device; Ambu; Ballerup, Denmark). Participants performed mask placement and delivery of 10 breaths per minute for three minutes, as guided by a metronome. After a three-minute rest period, they performed ventilation using the alternative device. The primary outcome measure was mean received tidal volume as measured by the manikin (IngMar RespiTrainer model; IngMar Medical; Pittsburgh, Pennsylvania USA). Secondary outcomes included subject device preference.
Results:
Of 70 recruited participants, all completed the study. The difference in mean received tidal volume between ventilations performed using the modified BVM with external handle versus standard BVM was 20 ml (95% CI, -16 to 56 ml; P=.28). There were no significant differences in mean received tidal volume based on the order of study arm allocation. The proportion of participants preferring the modified BVM over the standard BVM was 47.1% (95% CI, 35.7 to 58.6%).
Conclusions:
The modified BVM with added external handle did not result in greater mean received tidal volume compared to standard BVM during single rescuer ventilation in a manikin model. Reed P , Zobrist B , Casmaer M , Schauer SG , Kester N , April MD . Single rescuer ventilation using a bag valve mask with removable external handle: a randomized crossover trial. Prehosp Disaster Med. 2017;32(6):625-630.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...