Related Experiment Video
Updated: Feb 24, 2026

Percutaneous Contrast Echocardiography-guided Intramyocardial Injection and Cell Delivery in a Large Preclinical Model
Published on: January 21, 2018
Iodixanol versus Iopromide at Coronary CT Angiography: Lumen Opacification and Effect on Heart Rhythm-the Randomized
Marisa M Lubbers1, Marc Kock1, André Niezen1
1From the Departments of Cardiology (M.M.L., T.G., K.N.) and Radiology (M.M.L., M.D., R.B., A.P., A.V., R.P.J.B., K.N.), Erasmus Medical Center, 's-Gravendijkwal 230, Room Ca-207a, Rotterdam 3015 CE, the Netherlands; Departments of Radiology (M. Kock, S.K.) and Cardiology (M. Kofflard), Albert Schweitzer Ziekenhuis, Dordrecht, the Netherlands; and Departments of Radiology (A.N., H.v.V.) and Cardiology (T.B.), Maasstad Ziekenhuis, Rotterdam, the Netherlands.
Purpose To show that equal coronary lumen opacification can be achieved with iso- and low-osmolar contrast media when it is injected at the same iodine delivery rate with contemporary cardiac computed tomographic (CT) protocols and to investigate the cardiovascular effect of iso-osmolar contrast media and the image quality achieved. Materials and Methods Institutional review board approval and written informed consent were obtained for the Effect of Iso-osmolar Contrast Medium on Coronary Opacification and Heart Rhythm in Coronary CT Angiography, or IsoCOR, trial. Between November 2015 and August 2016, 306 patients (167 [55%] women) at least 18 years old (weight range, 50-125 kg), were prospectively randomized to receive iso-osmolar iodixanol 270 or low-osmolar iopromide 300 contrast media. All coronary segments were assessed for intraluminal opacification and image quality and were compared by using the Student t test. Heart rate, arrhythmia, patient discomfort, and adverse events also were monitored. Results Mean measured coronary attenuation values ± standard deviation were comparable between the iodixanol 270 and iopromide 300 contrast media groups (469 HU ± 167 vs 447 HU ± 166, respectively [P = .241]; 95% confidence interval: -15.1, 60.0), including those from subanalyses. Adjusted for the lower iodine concentration, the mean iodixanol 270 bolus was larger compared with that of iopromide 300 (76.8 mL ± 11.6 vs 69.7 mL ± 10.8, respectively; P < .001). The higher injection rate was associated with higher pressure (777 kPa ± 308 vs 630 kPa ± 252, respectively; P < .001). Although in the iodixanol 270 group patients experienced less heat discomfort (72% vs 86%, respectively; P < .001), no differences in heart rate or rhythm were observed. Conclusion If injected at comparable iodine delivery rates, the iso-osmolar contrast medium iodixanol 270 is not inferior to low-osmolar contrast medium iopromide 300 for assessment of coronary opacification. Iodixanol 270 was associated with less heat discomfort, but did not affect heart rate differently compared with iopromide 300. © RSNA, 2017 Online supplemental material is available for this article.
Purpose To show that equal coronary lumen opacification can be achieved with iso- and low-osmolar contrast media when it is injected at the same iodine delivery rate with contemporary cardiac computed tomographic (CT) protocols and to investigate the cardiovascular effect of iso-osmolar contrast media and the image quality achieved. Materials and Methods Institutional review board approval and written informed consent were obtained for the Effect of Iso-osmolar Contrast Medium on Coronary Opacification and Heart Rhythm in Coronary CT Angiography, or IsoCOR, trial. Between November 2015 and August 2016, 306 patients (167 [55%] women) at least 18 years old (weight range, 50-125 kg), were prospectively randomized to receive iso-osmolar iodixanol 270 or low-osmolar iopromide 300 contrast media. All coronary segments were assessed for intraluminal opacification and image quality and were compared by using the Student t test. Heart rate, arrhythmia, patient discomfort, and adverse events also were monitored. Results Mean measured coronary attenuation values ± standard deviation were comparable between the iodixanol 270 and iopromide 300 contrast media groups (469 HU ± 167 vs 447 HU ± 166, respectively [P = .241]; 95% confidence interval: -15.1, 60.0), including those from subanalyses. Adjusted for the lower iodine concentration, the mean iodixanol 270 bolus was larger compared with that of iopromide 300 (76.8 mL ± 11.6 vs 69.7 mL ± 10.8, respectively; P < .001). The higher injection rate was associated with higher pressure (777 kPa ± 308 vs 630 kPa ± 252, respectively; P < .001). Although in the iodixanol 270 group patients experienced less heat discomfort (72% vs 86%, respectively; P < .001), no differences in heart rate or rhythm were observed. Conclusion If injected at comparable iodine delivery rates, the iso-osmolar contrast medium iodixanol 270 is not inferior to low-osmolar contrast medium iopromide 300 for assessment of coronary opacification. Iodixanol 270 was associated with less heat discomfort, but did not affect heart rate differently compared with iopromide 300. © RSNA, 2017 Online supplemental material is available for this article.
More Related Videos
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Acute Coronary Syndrome I: Introduction
Ischemic Heart Disease: Overview
Atherosclerosis, the primary malefactor, orchestrates this dangerous condition. It manifests as the accumulation of fatty deposits, akin to insidious plaques, within arterial walls. As time elapses, these plaques metamorphose, hardening and...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT

