Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Flexural Stress01:16

Flexural Stress

794
When analyzing bending in symmetric members, it's crucial to understand how stresses distribute when subjected to bending moments. This stress distribution is effectively described by applying fundamental mechanics and material science principles, particularly Hooke's Law for elastic materials.
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to its distance...
794
Mechanical Systems01:22

Mechanical Systems

705
Mechanical systems are analogous to to electrical networks where springs and masses play similar roles to inductors and capacitors, respectively. A viscous damper in mechanical systems functions similarly to a resistor in electrical networks, dissipating energy. The forces acting on a mass in such systems include an applied force in the direction of motion, counteracted by forces from the spring, a viscous damper, and the mass's acceleration. This interplay of forces is mathematically...
705
Design Example: Frog Muscle Response01:14

Design Example: Frog Muscle Response

630
A student is tasked to work on an intriguing experiment involving an RL (Resistor-Inductor) circuit to study the muscle response of a frog's leg to electrical stimulation. The RL circuit plays a crucial role in this experiment, providing the means to control and measure the electrical impulses that trigger muscle contraction.
When the switch connecting the RL circuit is closed, a brief muscle contraction is observed. This is because, at a steady state, the inductor acts like a short...
630
Design of Transmission Shafts - Stress Analysis01:15

Design of Transmission Shafts - Stress Analysis

761
Designing a transmission shaft requires a thorough understanding of the stresses induced by bending moments and torques, especially in systems where power is transferred through gears. These forces create force-couple systems at the centers of the shaft's cross-sections, leading to both transverse and torsional loading. Although shearing stresses from transverse loads are typically smaller than those from torques and are often overlooked, the significant normal stresses from these loads...
761
Design of Transmission Shafts01:16

Design of Transmission Shafts

817
The design of a transmission shaft is governed by two primary specifications: the power it transmits and its rotational speed. These parameters guide the selection of the shaft's material and cross-sectional dimensions, ensuring that the material's maximum shearing stress remains within the elastic limit while transmitting the desired power at the given speed. The system's power is intrinsically linked to the applied torque. The torque applied to the shaft can be calculated by reconfiguring the...
817
Deformation of Member under Multiple Loadings01:11

Deformation of Member under Multiple Loadings

514
When a rod is made of different materials or has various cross-sections, it must be divided into parts that meet the necessary conditions for determining the deformation. These parts are each characterized by their internal force, cross-sectional area, length, and modulus of elasticity. These parameters are then used to compute the deformation of the entire rod.
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
514

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Study of the Influence of Visuo-Haptic Feedback on Prosthetic Embodiment.

IEEE transactions on haptics·2026
Same author

Augmenting natural skin stretch during active finger motion reshapes hand proprioception.

Journal of the Royal Society, Interface·2026
Same author

Accurate and affordable cobot calibration without external measurement devices.

Communications engineering·2026
Same author

Overview of an ongoing clinical trial on hand prostheses: Toward use of synergy-based prosthetic hands for activities of daily living by transradial amputees.

IEEE transactions on bio-medical engineering·2026
Same author

The softfoot pro at the cybathlon: kinematic, metabolic, and user performance evaluation.

Journal of neuroengineering and rehabilitation·2026
Same author

The SoftFoot Pro: an anthropomorphic and adaptive soft articulated prosthetic foot.

Nature communications·2026

Related Experiment Video

Updated: Feb 24, 2026

Author Spotlight: Enhancing Grasping Abilities for Hemiplegic Patients with Flexible Robotic Limbs
03:55

Author Spotlight: Enhancing Grasping Abilities for Hemiplegic Patients with Flexible Robotic Limbs

Published on: October 27, 2023

2.9K

Design, control and validation of the variable stiffness exoskeleton FLExo.

Sariah Mghames, Marco Laghi, Cosimo Della Santina

    IEEE ... International Conference on Rehabilitation Robotics : [Proceedings]
    |August 18, 2017
    PubMed
    Summary

    This study introduces an assistive exoskeleton with a novel variable stiffness actuator that mimics human muscles. This device significantly reduces upper limb muscle effort during tasks.

    More Related Videos

    Design and Fabrication of an Elastomeric Unit for Soft Modular Robots in Minimally Invasive Surgery
    11:06

    Design and Fabrication of an Elastomeric Unit for Soft Modular Robots in Minimally Invasive Surgery

    Published on: November 14, 2015

    9.4K
    Development of a Novel Task-oriented Rehabilitation Program using a Bimanual Exoskeleton Robotic Hand
    06:44

    Development of a Novel Task-oriented Rehabilitation Program using a Bimanual Exoskeleton Robotic Hand

    Published on: May 20, 2020

    7.6K

    Related Experiment Videos

    Last Updated: Feb 24, 2026

    Author Spotlight: Enhancing Grasping Abilities for Hemiplegic Patients with Flexible Robotic Limbs
    03:55

    Author Spotlight: Enhancing Grasping Abilities for Hemiplegic Patients with Flexible Robotic Limbs

    Published on: October 27, 2023

    2.9K
    Design and Fabrication of an Elastomeric Unit for Soft Modular Robots in Minimally Invasive Surgery
    11:06

    Design and Fabrication of an Elastomeric Unit for Soft Modular Robots in Minimally Invasive Surgery

    Published on: November 14, 2015

    9.4K
    Development of a Novel Task-oriented Rehabilitation Program using a Bimanual Exoskeleton Robotic Hand
    06:44

    Development of a Novel Task-oriented Rehabilitation Program using a Bimanual Exoskeleton Robotic Hand

    Published on: May 20, 2020

    7.6K

    Area of Science:

    • Robotics
    • Biomechanics
    • Assistive Technology

    Background:

    • Upper limb assistive devices often lack natural control and force feedback.
    • Existing exoskeletons may not effectively replicate human muscle dynamics.
    • Controlling assistive devices based on biological muscle parameters remains a challenge.

    Purpose of the Study:

    • To design and validate a one-degree-of-freedom assistive platform for upper limb strength augmentation.
    • To develop a novel control strategy that maps muscle activation directly to exoskeleton behavior.
    • To investigate the efficacy of a variable stiffness actuator that mimics antagonistic muscle function.

    Main Methods:

    • Development of a variable stiffness actuator replicating antagonistic muscle pairs.
    • Implementation of a control system mapping estimated muscle activations (via ElectroMyoGraphic (EMG) sensors) to the exoskeleton.
    • Tuning of mechanical parameters to achieve analogy with human muscle system threshold lengths.
    • Experimental validation of the platform and control strategy.

    Main Results:

    • The assistive platform successfully augmented upper limb strength.
    • The novel control strategy effectively exploited the muscle-like dynamics of the actuator.
    • Experimental results demonstrated a substantial reduction in subject muscle effort.
    • The exoskeleton joint stiffness was inherently controlled through the mapping strategy.

    Conclusions:

    • The developed assistive platform and its muscle-analogue control strategy are effective.
    • This approach offers a promising method for enhancing human-machine interaction in assistive robotics.
    • The findings suggest potential for more intuitive and effective upper limb exoskeletons.