Related Experiment Video
Updated: Feb 24, 2026

Modeling Fast-scan Cyclic Voltammetry Data from Electrically Stimulated Dopamine Neurotransmission Data Using QNsim1.0
Published on: June 5, 2017
[Application of DOSC combined with SBC in batches transfer of NIR quantitative model]
Yi-Fei Jia1, Ying-Ying Zhang1, Bing Xu1
1Beijing University of Chinese Medicine, Beijing 100102, China.
Abstract:
Near infrared model established under a certain condition can be applied to the new samples status, environmental conditions or instrument status through the model transfer. Spectral background correction and model update are two types of data process methods of NIR quantitative model transfer, and orthogonal signal regression (OSR) is a method based on spectra background correction, in which virtual standard spectra is used to fit a linear relation between master batches spectra and slave batches spectra, and map the slave batches spectra to the master batch spectra to realize the transfer of near infrared quantitative model. However, the above data processing method requires the represent activeness of the virtual standard spectra, otherwise the big error will occur in the process of regression. Therefore, direct orthogonal signal correction-slope and bias correction (DOSC-SBC) method was proposed in this paper to solve the problem of PLS model's failure to predict accurately the content of target components in the formula of different batches, analyze the difference between the spectra background of the samples from different sources and the prediction error of PLS models. DOSC method was used to eliminate the difference of spectral background unrelated to target value, and after being combined with SBC method, the system errors between the different batches of samples were corrected to make the NIR quantitative model transferred between different batches. After DOSC-SBC method was used in the preparation process of water extraction and ethanol precipitation of Lonicerae Japonicae Flos in this paper, the prediction error of new batches of samples was decreased to 7.30% from 32.3% and to 4.34% from 237%, with significantly improved prediction accuracy, so that the target component in the new batch samples can be quickly quantified. DOSC-SBC model transfer method has realized the transfer of NIR quantitative model between different batches, and this method does not need the standard samples. It is helpful to promote the application of NIR technology in the preparation process of Chinese medicines, and provides references for real-time monitoring of effective components in the preparation process of Chinese medicines.
More Related Videos
Related Concept Videos
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Dose Size and Dosing Frequency: Determination Methods
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This...
Compartment Models: Single-Compartment Model

