Related Experiment Video
Updated: Feb 24, 2026

Adjustable Stiffness, External Fixator for the Rat Femur Osteotomy and Segmental Bone Defect Models
Published on: October 9, 2014
Biomechanical comparison of a novel monocortical and two common bicortical external fixation systems regarding
Patrick A Varady1,2, Markus Greinwald1,2, Peter Augat1,2
1Institute of Biomechanics, Trauma Center Murnau, Murnau, Germany.
Aim:
To biomechanically compare a monocortical single frame external fixator (Orthofix UNYCO) with two bicortical fixator systems (dual frame: Stryker Hoffmann and single frame: Synthes LEF) with respect to system rigidity and stability under cyclic loading.
Methods:
The fixator systems were assessed for axial rigidity under loads which would occur clinically during fixator application and dynamic stability (cyclic fatigue) under loads which would occur in the first week postoperatively. Tests were performed on porcine tibiae (n>5 per group) with characteristic frame configurations. Loads were applied with an electrodynamic material testing machine and pin and frame deformations were continuously monitored with a marker based motion capturing system.
Results:
The bicortical single frame fixator revealed the largest rigidity (276±55) N/mm and was 20% (p=0.116) stiffer compared to the bicortical dual frame configuration and 39% (p=0.003) stiffer compared to the monocortical system. All systems survived 4000 cycles of loading, with the smallest vertical displacement (2.44±0.54 mm) observed for the bicortical dual frame system, followed by the monocortical single frame (3±0.55 mm, p=0.85) and bicortical single frame (3.25±0.96 mm, p=0.215).
Conclusion:
The monocortical fixation system performed comparably to the bicortical systems for its intended use as a temporary treatment before a definitive fracture osteosynthesis by plating or nailing.
More Related Videos
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
Related Concept Videos
Stability of structures
Applications of Stress
The...
Eccentric Axial Loading in a Plane of Symmetry
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...
Constraints and Statical Determinacy
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity