Kui Zeng1, Zongming Gao2, Michael Trehy2
1Division of Pharmaceutical Analysis, Office of Testing and Research, Center for Drug Evaluation and Research, United States Food and Drug Administration, 645 S. Newstead Avenue, St Louis, Missouri, USA. kui.zeng@fda.hhs.gov.
Abstract:
Tacrolimus is a potent, narrow therapeutic index, immunosuppressive drug used to avoid organ rejection in patients that have undergone organ transplantation. Dissolution tests are widely used to evaluate drug product quality and performance. Analysis of tacrolimus during dissolution testing is sensitive to several factors, such as sample solution storage time and container material. The filtration process, tacrolimus glass adsorption, and sample solution storage time are found to impact the tacrolimus dissolution results. Based on observations in this work, the use of G4 or equivalent filter flush before collection and polypropylene test tubes or vials instead of glass test tubes or vials are recommended for tacrolimus drug product dissolution test.