Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

¹H NMR: Interpreting Distorted and Overlapping Signals01:02

¹H NMR: Interpreting Distorted and Overlapping Signals

1.6K
Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
1.6K
NMR Spectrometers: Overview01:20

NMR Spectrometers: Overview

2.3K
NMR spectrometers consist of a strong magnet, a radiofrequency transmitter, and a detector attached to a computer console for recording spectra of samples containing NMR-active nuclei. In first-generation NMR instruments called continuous-wave spectrometers, the resonance frequencies of the nuclei are determined by frequency-sweep or field-sweep methods. The magnetic field strength is fixed and the rf signal is swept in the former, while the radiofrequency signal is fixed and the magnetic field...
2.3K
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

1.1K
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.1K
NMR Spectroscopy: Spin–Spin Coupling01:08

NMR Spectroscopy: Spin–Spin Coupling

3.3K
The spin state of an NMR-active nucleus can have a slight effect on its immediate electronic environment. This effect propagates through the intervening bonds and affects the electronic environments of NMR-active nuclei up to three bonds away; occasionally, even farther. This phenomenon is called spin–spin coupling or J-coupling. Coupling interactions are mutual and result in small changes in the absorption frequencies of both nuclei involved. While nuclei of the same element are involved...
3.3K
¹³C NMR: ¹H–¹³C Decoupling01:04

¹³C NMR: ¹H–¹³C Decoupling

1.9K
The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
1.9K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Distance Computation Based on Coupled Spin-Torque Oscillators: Application to Image Processing.

Physical review applied·2026
Same author

Quality by Design Approach for Hot-Melt Extrusion Coupled Fused Deposition Modeling (HME-FDM) 3D Printing: A Systematic Review.

Pharmaceutics·2026
Same author

Thermosensitive in situ gels for ocular drug delivery: Advances in polymer-based formulations.

European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences·2026
Same author

Design rules for low-insertion-loss magnonic transducers.

Scientific reports·2025
Same author

The effect of Ga-ion irradiation on sub-micron-wavelength spin waves in yttrium-iron-garnet films.

Nanotechnology·2025
Same author

Design of oscillatory neural networks by machine learning.

Frontiers in neuroscience·2024
Same journal

Application of ephrin-B2 loaded glycol chitosan-silk fibroin hydrogel in the treatment of diabetic refractory wounds.

Scientific reports·2026
Same journal

International expert Delphi consensus on thromboprophylaxis in metabolic and bariatric surgery.

Scientific reports·2026
Same journal

Assessing the cross-region knowledge transfer capability of selected deep learning building vectorization methods in the context of available training datasets.

Scientific reports·2026
Same journal

Feasibility and preliminary effects of outdoor versus indoor cognitive-motor therapy in women with Alzheimer's disease: A randomized single-blind pilot study.

Scientific reports·2026
Same journal

Hallmarks of social action in the vocal turn-taking of wild common marmosets (Callithrix jacchus).

Scientific reports·2026
Same journal

Role and mechanism of AOPPs-induced NOX4-mediated ferroptosis in intervertebral disc degeneration.

Scientific reports·2026
See all related articles

Related Experiment Video

Updated: Feb 24, 2026

Implementation of a Reference Interferometer for Nanodetection
16:11

Implementation of a Reference Interferometer for Nanodetection

Published on: April 26, 2014

9.8K

Nanoscale spectrum analyzer based on spin-wave interference.

Ádám Papp1,2, Wolfgang Porod1, Árpád I Csurgay2

  • 1Center for Nano Science and Technology University of Notre Dame (ND nano), Notre Dame, IN, USA.

Scientific Reports
|August 25, 2017
PubMed
Summary
This summary is machine-generated.

This study introduces a novel spin-wave device for microwave signal processing. This magnetoelectric technology offers potential for faster, smaller, and more power-efficient signal processing compared to traditional electrical systems.

More Related Videos

High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis
07:55

High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis

Published on: September 22, 2017

10.7K
Measurement of Scattering Nonlinearities from a Single Plasmonic Nanoparticle
15:06

Measurement of Scattering Nonlinearities from a Single Plasmonic Nanoparticle

Published on: January 3, 2016

13.4K

Related Experiment Videos

Last Updated: Feb 24, 2026

Implementation of a Reference Interferometer for Nanodetection
16:11

Implementation of a Reference Interferometer for Nanodetection

Published on: April 26, 2014

9.8K
High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis
07:55

High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis

Published on: September 22, 2017

10.7K
Measurement of Scattering Nonlinearities from a Single Plasmonic Nanoparticle
15:06

Measurement of Scattering Nonlinearities from a Single Plasmonic Nanoparticle

Published on: January 3, 2016

13.4K

Area of Science:

  • Physics
  • Electrical Engineering
  • Materials Science

Background:

  • Microwave signal processing traditionally relies on electrical components.
  • Existing electrical systems face limitations in speed, size, and power consumption.
  • Spin-wave excitations offer a potential alternative for signal manipulation.

Purpose of the Study:

  • To design and analyze a novel spin-wave-based microwave signal processing device.
  • To explore the potential of magnetoelectric devices for advanced signal processing applications.
  • To compare the performance of spin-wave devices with conventional electrical systems.

Main Methods:

  • Design of a device utilizing spin-wave excitations in a patterned magnetic thin-film.
  • Conversion of microwave signals into spin-wave excitations.
  • Formation and analysis of spin-wave interference patterns.
  • Verification and analysis using analytic calculations and micromagnetic simulations.

Main Results:

  • The device successfully performs spectral decomposition of microwave signals via spin-wave interference.
  • Analytic calculations and micromagnetic simulations confirm the device's operational principles.
  • Projected performance metrics (speed, area, power consumption) at room temperature are significantly superior to electrical systems.
  • Demonstrated potential for a new class of low-power, high-speed signal processors.

Conclusions:

  • Spin-wave-based devices offer a promising avenue for next-generation microwave signal processing.
  • Magnetoelectric devices leveraging spin waves can overcome limitations of current electrical technologies.
  • This technology paves the way for highly efficient, specialized signal processing applications.