On homogeneity approximation in calibration of gamma-spectrometry assessment of bulk samples
1Physics Department, University of Bucharest, Bucharest-Magurele 077125, Romania.
Abstract:
The effect of the intrinsic inhomogeneity of a sample on the efficiency for the measurement of the sample by gamma-ray spectrometry is studied. The difference between the efficiency for the inhomogeneous sample and the efficiency for a sample made from the equivalent homogeneous matrix is evaluated.
Related Concept Videos
Instrument Calibration
873
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
873
High-Resolution Mass Spectrometry (HRMS)
2.7K
The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
2.7K
Atomic Absorption Spectroscopy: Lab
1.1K
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
1.1K
Gas Chromatography–Mass Spectrometry (GC–MS)
7.0K
Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
7.0K
Calibration Curves: Linear Least Squares
4.6K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
For data that follow a straight line, the standard method for fitting is the linear...
4.6K
Contaminants and Errors
411
Effective sample preparation is crucial for accurate and reliable laboratory analysis. During this process, two significant sources of error can arise: concentration bias from improper sample splitting and contamination caused by methods used to reduce particle size, such as grinding or homogenization. Identifying and minimizing these potential errors is crucial to ensuring the validity of the analysis.
Another key consideration is determining the appropriate number of samples required to...
Another key consideration is determining the appropriate number of samples required to...
411