Related Experiment Video
Updated: Feb 24, 2026

Sampling and Pretreatment of Tooth Enamel Carbonate for Stable Carbon and Oxygen Isotope Analysis
Published on: August 15, 2018
Measuring 13 C-enriched CO2 in air with a cavity ring-down spectroscopy gas analyser: Evaluation and calibration
Dane Dickinson1, Samuel Bodé2, Pascal Boeckx2
1Biosystems Engineering, Ghent University, Coupure Links 653, 9000, Gent, Belgium.
Rationale:
Cavity ring-down spectroscopy (CRDS) is becoming increasingly popular for δ13 C-CO2 analysis of air. However, little is known about the effect of high 13 C abundances on the performance of CRDS. Overlap between 12 CO2 and 13 CO2 spectral lines may adversely affect isotopic-CO2 CRDS measurements of 13 C-enriched samples. Resolving this issue is important so that CRDS analysers can be used in CO2 flux studies involving 13 C-labelled tracers.
Methods:
We tested a Picarro G2131-i CRDS isotopic-CO2 gas analyser with specialty gravimetric standards of widely varying 13 C abundance (from natural to 20.1 atom%) and CO2 mole fraction (xCO2 : <0.1 to 2116 ppm) in synthetic air. The presence of spectroscopic interference between 12 CO2 and 13 CO2 bands was assessed by analysing errors in measurements of the standards. A multi-component calibration strategy was adopted, incorporating isotope ratio and mole fraction data to ensure accuracy and consistency in corrected values of δ13 C-CO2 , x12 CO2 , and x13 CO2 .
Results:
CRDS measurements of x13 CO2 were found to be accurate throughout the tested range (<0.005 to 100 ppm). On the other hand, spectral cross-talk in x12 CO2 measurements of standards containing elevated levels of 13 CO2 led to inaccuracy in x12 CO2 , total-xCO2 (x12 CO2 + x13 CO2 ), and δ13 C-CO2 data. An empirical relationship for x12 CO2 measurements that incorporated the 13 C/12 C isotope ratio (i.e. 13 CO2 /12 CO2 , RCO2) as a secondary (non-linear) variable was found to compensate for the perturbations, and enabled accurate instrument calibration for all CO2 compositions covered by our standard gases.
Conclusions:
13 C-enrichement in CO2 leads to minor errors in CRDS measurements of x12 CO2 . We propose an empirical correction for measurements of 13 C-enriched CO2 in air by CRDS instruments such as the Picarro G2131-i.
Related Concept Videos
Measurement of Air Content in Concrete
The pressure method,...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Carbon-13 (¹³C) NMR: Overview
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...

